C. BLOISE - CSN1 – ROMA, 22 GENNAIO 2013 STATO E PIANI DI KLOE-2.

Slides:



Advertisements
Presentazioni simili
R P Rivelazione Acustica Particelle A bassa temperatura e in Superconduttori Sommario problematica e risultati Nautilus Attivita svolta Programma del prossimo.
Advertisements

L.Mandelli _CSN1_Settembre 02 LAr 2003 Stato della calorimetria Elettromagnetica Stato delle responsabilità INFN. Attività e responsabilità future del.
Prototipi: stato e risultati G. Cibinetto INFN – Universita di Ferrara Roma, 16 Giugno 2003.
Stato delle SDD Installate in ALICE già a inizio 2007 Nel 2008 Messa a punto di cooling/DAQ/controlli Sviluppo del software di monitor e analisi Run con.
TISB Firenze 15 – 16 Gennaio 2003 Ricerche di SUSY con CMS: alcuni commenti e idee… Alessia Tricomi Dipartimento di Fisica and INFN Catania.
LHCf Status Report Measurement of Photons and Neutral Pions in the Very Forward Region of LHC Oscar Adriani INFN Sezione di Firenze - Dipartimento di Fisica.
50×50 mm 2 CsI(Tl) 0.8 mm pitch M = 2, FoV = 25×25 mm 2 50×50 mm 2 LaBr 3 (Ce) 4 mm thick, 3 mm thick window M = 2, FoV = 25×25 mm 2 50×50 mm 2 CsI(Na)
A. Di Ciaccio Riunione RPC 17 luglio 2002 Lecce Test ad X5-GIF (3-10 luglio 2002) Scopi del test (discussi tra di noi,con i referee ed al GruppoI a giugno)
Come fanno i ricercatori a vedere le particelle?
VIPIX, pSuperB, (SuperB) Atlas/FTK M. Villa 04/11/2010.
Commissione 1, Roma, 3 Aprile 2007M. Villa Stato del LUCID M. Villa per il LUCID group Storia recente Nuova strategia rivelatore Tests su fascio Tests.
1 referee-ATLAS CSN I, Roma 2-3/4/2007 RELAZIONE DEI REFEREE DI ATLAS F. Bedeschi, R. Carlin, S. Dalla Torre, N. Pastrone 3 aprile 2007.
C. Labanti - Gen 04 Rivelatori per INTEGRAL ed AGILE IASF-BO Sezione di Bologna 2001 ESTEC-NL 2003 Roma.
CMS RPC R&D for phase 2 Two types of upgrades proposed for the CMS RPC muon system: 1.Aging and longevity: installed in 2007, must continue to operate.
Sezione di Padova Contributo alla costruzione dei layers 6,7 Possibili task per PADOVA:  precedente proposta: R&D della procedura di assemblaggio degli.
G. Costa, Roma 16 maggio 2006 Commissione I LAr: status report 1.
P-ILC Breve stato delle cose CSN1 - 6 febbraio 2006 M.Caccia Uni. Insubria & INFN Milano  inizio attivita’ a Roma 1 & LNF  sviluppo di sensori SOI -
Total Cross Section, Elastic Scattering and Diffraction Dissociation at the LHC CSN1 - 6 luglio TOTEM – luglio 2005 Politecnico di Bari and Sezione.
CMS RPC R&D for phase 2 Two types of upgrades proposed for the CMS RPC muon system: 1.Aging and longevity: installed in 2007, must continue to operate.
Attivita` di TileCal 2013 C.Roda Universita` e INFN Pisa Riunione referees ATLAS Roma 1 C.Roda Universita` e INFN Pisa.
M. Citterio Roma 10 Gennaio 2006 Costo per l’upgrade del Calorimetro Elettromagnetico ad Argon Liquido di Atlas Mauro Citterio INFN Milano.
Nicolo` Cartiglia Stato dell'elettronica di ECAL - La situazione e' in continua evoluzione. Entro l'estate si formalizzera` la decisione su quale elettronica.
Stato degli RPC di ATLAS Riunione CSN1 Catania 19/9/02 R. Santonico.
18 Set 2008 JLab12.0 JLab e CEBAF JLab12 Prima Riunione Plenaria 18 Settembre m 5 Recirculation Arcs 0.6 GeV Linac Extraction element End Stations.
ATLAS MDT Italia Status report Stato della produzione Test beam Costi Conclusioni M. Livan Gruppo I Roma
F. Marchetto – INFN- Torino GigaTracKer: status report 25 Maggio Update su infra-structures 2. Stato del cooling 3.Bump-bonding e thinning 4. Stato.
THE LIGHT How does the light propagate?. 1)To verify that light propagates in straight lines 2)To compare an object with its projection on a rigid screen.
"3+L"... Time Resolved e+ Light Proposta per il gruppo V A.Drago (coord.) A.Bocci, M. Cestelli Guidi, A. Clozza, A. Grilli, A. Marcelli.
5 febbraio Stato del commissioning di MEG: (ricerca del decadimento   e  con sensibilita’ ) A. M. Baldini INFN Pisa.
I sistemi di gas dei rivelatori di muoni del barrel di CMS (DT e RPC) Paolo Giacomelli - INFN Bologna.
MUG-TEST A. Baldini 29 gennaio 2002
Trieste M. Diemoz - INFN Roma ECAL Settembre 2006.
1 6 maggio 2009Attivita' e richieste CSM Frascati - Stefano Bianco 1 ATTIVITA` CMS FRASCATI MAGGIO )Sistema Gas Gain Monitoring (GGM) 2)Studio dei.
CSN1, 17 settembre 2002 COMPASS prospettive verso la fase 2: tempi ed impegni italiani previsti F. Bradamante attivita’ della collaborazione per la fase.
CSN M. Diemoz CMS – RRB24 SOLDI INVESTITI BENE...
15.11,2005 LNFMarcello A Giorgi1 Marcello A. Giorgi Università di Pisa and INFN Pisa ROADMAP B and SUPER B in Italia Gruppo1 LNF 15Novembre, 2005.
Proposta Upgrade activities for Rome in 2014 Francesca 1.
P5  2009 shifts VS shifts until the end of 2009  2010 plan.
L. Carminati - P. GovoniIII Workshop sull fisica di ATLAS-CMS1 sessione di discussione uno spunto: la calibrazione in situ dei rivelatori CALORIMETRI ELETROMAGNETICI:
1 6 maggio 2009Attivita' e richieste CSM Frascati - Stefano Bianco 1 Closed Loop e Gas Gain Monitoring Il Closed Loop e’ in operazione stabile dopo lo.
CMS RPC ITALIA' , Settembre Ischia-ITALIA RPC DCS Giovanni Polese.
News LHC recommissioning is continuing Sucessfully achieved so far 4 TeV beams, 0.6 m beta* (at least with few bunches) Some beam splashes last week; still.
LSPE-SWIPE Crate for readout electronics 3 Nov 2014 Marco Incagli, Franco Spinella.
Km3 – KM3NeT: stato delle attività Torre di NEMO – Fase2 Costruzione delle 8 Torri e della rete di fondo (M. Anghinolfi) Preparazione della costruzione.
What’s new in KLOE-2? Testing procedures after assembly: Tests with X-ray gun (6 KeV source) for gain measurements (I-V curve) Tests with  source for.
Vincenzo Bellini Università di Catania Contributo al “Fourth Jlab12 Annual Meeting” ROMA 10 Giugno 2010 Dipartimento di Fisica ed Astronomia.
S VILUPPO ELETTRONICA PER EMC BELLEII INFN ROMA3 Diego Tagnani 10/06/2014 ROMA 3 : D. P.
G-2 It G. Venanzoni LNF/INFN G-2 IT Meeting, Fiume Ottobre
Status of the INFN Camera F. Giordano INFN - Bari For the CTA-INFN Team Bari - CTA F2F MeeingSITAEL 11 Marzo 2015.
Interessi e richieste finanziarie per IBL. 2 IBL Lay-out 2  Since IBL is an additive layer, its radiation length has to be extremely small  Geometry.
Lina, Paolo, Tonino, Riccardo.   An assessment of the need for a photo-production facility and its design  The neutron part should not exceed 20 pages.
Richieste IFR 2011 Roberto Calabrese Università e INFN – Ferrara Marzo 2011.
1 OUTLINE CSN I, Roma 19-20/1/2015 RICH&THGEMSilvia DALLA TORRE Impegni per costruzioni – bilancio 2014 Read-out rivelatori ibridi ottobre 2014 – gennaio.
Elettronica Monitoring, DAQ 27 Aprile 2016 M. Iacovacci, S. Mastroianni, O. Escalante, P. Di Meo.
TGC upgrade for SLHC (ATL-P-MN-0028 ) Fra le parti più colpite dall’aumento di rate previsto a SLHC ci sono le Small Wheels Le TGC con catodo a bassa resistività.
CSN1 Apr Relazione Referee KLOE Paolo Checchia Riccardo Fantechi Pierluigi Paolucci Luca Lista Ezio Menichetti.
CALOCUBE SVILUPPO DI CALORIMETRIA OMOGENEA AD ALTA ACCETTANZA PER ESPERIMENTI DI RAGGI COSMICI NELLO SPAZIO 1^ CaloCube meeting Firenze, 20 Giugno 2014.
Totale FTE tecnico elettronico 1 tecnico meccanico G.C.Barbarin o P.O.KM350% P.Migliozzi1 Ric. INFNKM380% C.MolloAssegno KM3KM380% G.DerosaRic. UKM330%
TOTEM review a LHCC C. Cecchi CSN1, Parma 24/09/2010 CSN1, Parma 23/09/10C. Cecchi  STATO DELL’ESPERIMENTO & PHYSICS PLAN 2010/2011  INSTALLAZIONE DI.
17/09/2008CSN1 Pisa1 KLOE: referee* Stato dell’arte Linee guida Dettagli Proposte 2008 Proposte 2009 Milestones *E. Menichetti, P. Paolucci, P.C.+ ref.
MM news & status -Final Design Review -NA for NSW -altre attività MM.
Project IOLI Practical exemple in Italy and in Sicily Il presente progetto è finanziato con il sostegno della Commissione europea. L’autore è il solo responsabile.
KLOE F. Bossi CSN1 LNF 24 Novembre Commento sui risultati di DA  NE I risultati ottenuti nelle ultime settimane da DANE sono estremamente.
Michele Iacovacci (Napoli),
Calorimetro LAR ATLAS Italia Roma 28 novembre 2008
Accelerator Disision March 3rd 2015
PROBLEMA: Lo slow shaper, o comunque qualcosa tra preamplificatore e ADC, mostra un guadagno almeno dieci volte inferiore a quello dichiarato per MAROC3.
Preliminary results of DESY drift chambers efficiency test
WP2: Protocollo, Gestione esame, Adeguamento Facility
CdS 2017: embargo fino a TAUP2017
Transcript della presentazione:

C. BLOISE - CSN1 – ROMA, 22 GENNAIO 2013 STATO E PIANI DI KLOE-2

OUTLINE Stato e piani di DAFNE Data taking in Nov-Dec Nuova richiesta per il ripristino di operativita’ dell’apparato Pubblicazioni Shutdown, lavori in corso Gli upgrade di KLOE Integrazione, nuova zona d’interazione Conclusioni 2

DA SETTEMBRE... Il 19 settembre circolavano i primi fasci in DAFNE dopo lo shutdown estivo e il riallineamento dell’IP Si e’ proceduto: alla verifica dell’allineamento dell’IP; ottimizzazione della posizione di QD0, QF1 alle misure e matching dell’ ottica della macchina (25 ott-8 nov) ottimizzazione della luminosita’ senza sestupoli per il CW (L peak ~1.1*10 32 cm -2 s -1 ) allineamento dei sestupoli per il CW (Nov 12) test di stabilita’ di operazione la notte e nei weekend: data taking 1 nov – 15 dic Raccolti 4 pb-1 in 12 ore, L peak ~1.4*10 32 cm -2 s -1 Integrati ~100 pb-1 3

Conclusioni al CS (20 nov) DAFNE performances have been recovered in two months of operation Peak and hourly integrated luminosity are comparable with the best value achieved before summer, although the CW-Sextupoles are presently set at half of their nominal strength Beam based procedure to align magnetic elements in the IR have been well established Relevant limiting factor as optics non-reproducibility have been understood and fixed A detailed plan has been done to consolidate the DAFNE accelerator complex in order to get a higher uptime and a more reliable operation. The upgrade will be done in the shadow of the inner-tracker installation inside the KLOE detector Several options can still be explored to push peak and integrated luminosity toward higher values. C. Milardi

Steps toward higher Luminosity 1.Optics 2.Stronger crab waist sextupoles 3.Beam dynamics optimization 4.Higher beam currents 5.More bunches (102  ) 6.New power supplies for e-cloud clearing electrodes 7.Machine studies and fine tuning 8.Better vacuum (conditioning, scrabbing) 9.Improved injection by implementing fast kickers 10.Higher uptime coming from more reliable & stable subsystem C. Milardi da 2.x fb-1/year a 3.5 fb-1

LAVORI DI CONSOLIDAMENTO A meta’ dicembre DAFNE e’ stata spenta Una settimana fa e’ stata estratta la zona d’interazione Sono previsti interventi sul LINAC, sugli alimentatori di diversi magneti, sul sistema per il vuoto, sulla criogenia, sulla radiofrequenza, sugli elettrodi per l’e-cloud, sul sistema di controllo, e sull’impianto a fluidi Per la zona d’interazione Modifica raccordo sfera in albemet con la BP in Al: test di lavorazione a Foligno superato Schermi in Be : confermata la data del 15 marzo per la consegna irrobustimento del sostegno in fibre di carbonio: aggiunta di un sostegno centrale modifica del supporto; irrobustimento, passaggio cooling, cavi cooling IP 6

7 DATA TAKING Monitoring continuo di DAFNE (calorimetro) DAQ completo e camera accesa di notte e nei weekend La collaborazione Amadeus ha inserito na targhetta sottile di C sulla parete della camera per studiare le interazioni K - N: 100 pb-1 permettono di triplicare il campione selezionato nei dati di KLOE Test di data storage al CNAF, studio ed esercizio dei sistemi di calibrazione e ricostruzione Selezione dei Bhabha e calibrazione del calorimetro modificate per tener conto dell’alto rate di casuali. Buona qualita’ dei dati raccolti DAQ e monitoring : OK a parte problemi di interruzione del sistema correlato a perdite di fascio FEE ed efficienza di presa dati : preoccupante il numero e la lunghezza degli interventi di ripristino conseguenti alla rottura dei radiatori per il raffreddamento dell’alimentazione dei rack. 13 radiatori sostituiti e spare esauriti. Le perdite hanno causato corti su diverse schede e sul backplane di un crate Necessaria la sostituzione dei vecchi radiatori (115): spesa non prevista a settembre

8 K S K L →π + π − π + π − : CPT&Lorentz invDraft in preparation DISCRETE-12  S →       Draft circulated to the CollabPoS(EPS-HEP2011)182 Kaon regenerationIn progress PhD Thesis: Jag. U. Krakow   →      − In progressPoS(EPS-HEP2011)182  → π + π − π 0 In progress PhD Thesis: Uppsala U.  →  e + e −  →    −    →        TFF In progress PhD Thesis: Jag. U. Krakow BR(  →    −  ); dN/dm  PLB 718 (2013) 910  →       In progress PhD thesis: Uppsala U.  ’ →  In progress  →  →    −    →        JHEP 01 (2013) 119  → π 0 π 0 In progress PhD Thesis: Rm3  had :  Accepted by PLBPoS(EPS-HEP2011)376  (  ): evidence for VP In progress PhD Thesis: Messina U. ϕ →  e + e −,  → π + π − π 0 PLB 706 (2012) 1917 U-boson searches ϕ →  e + e −,  → π 0 π 0 π 0 Accepted by PLB e + e − →μ + μ − + missing energy In progress e + e − →e + e −  In progress Pubblicazioni

DARK FORCES: EXCLUSION PLOT M U (MeV) 22 →U→U ee→Uee→U ε2ε2

DETECTOR UPGRADES D. SC.LNF Inner Tracker QCAL CCAL

11 INNER TRACKER 4 layers at 13/15.5/18/20.5 cm from IP and 700 mm active length  r φ  250 µm and  z  400 µm XV strips-pads readout 2% X 0 total radiation length in the active region 3 mm 2 mm Cathode GEM 1 GEM 2 GEM 3 Anode Read-out Cylindrical Triple GEM FEE boards

Si sta assemblando l’ultimo layer, pronto a fine gennaio III e IV layer hanno gli elettrodi irrigiditi da una griglia per evitare deformazioni termiche Test sui layer 1-III con sorgenti e CR mostrano la funzionalita’ del rivelatore e dell’elettronica associata A meta’ febbraio la camera verra’ assemblata e testata L’integrazione sulla beam pipe a partire da meta’ marzo 12 STATO DI REALIZZAZIONE Layer 1 Layer 2 Layer 3

FEE 90 SR SOURCE SCAN 13D. SC.LNF X-view Hits distribution V strips not illuminated V-view Hits distribution FEE

14 COSMIC RAYS TEST tracking provided by external 10x10 cm 2 Triple-GEM Test with final HV cables and distributors, final FEE and DAQ system top/bottom scintillators for trigger

COSMIC RAYS TEST D. SC.LNF 3D view Z vs X (Lego View) noise cosmic tracks

QCALT calorimeter consists of 2 dodecagonal structures Each calorimeter is build in 2 halves to be coupled during insertion to the beam pipe. Each module (1/12), consists of a sampling calorimeter with 16 towers, composed by 5 layers of scintillator tiles and 5 layers of W/Cu absorbers Multicladding WLS fibers readout by 1.2 mm Ø circular, custom SiPM are coupled to the tiles for light transport For a total of 2000 TDC’s 16 QCALT: DETECTOR

Costruzione del calorimetro completata la settimana scorsa Tutte le tile montate sono state testate con una sorgente di 90 Sr source per controllare il contatto tile-fibre LY controllato coi CR. Fibre lucidate all’estremita’, pronte per il montaggio della schedina di FEE. Le basette inutilizzabili sono state riprodotte dalla Aurel ed il montaggio dei SiPM completato a dicembre dall’Advansid 17 STATO DI REALIZZAZIONE Half QCALT with W/Cu shielding Fiber holder Tiles/WLS stack After polishing Test della catena completa di acquisizione Test beam di un modulo alla BTF in feb

forward plate 8 aluminum shells LYSO crystals produced by SICCAS PCB housing SiPM and calibration LED shell and PCB holder QD0 coupling plate CCALT CCALT 1 calorimeter/side, 4 shells/calo, 3 modules/shell, 4 LYSO crystals/module

INTEGRAZIONE 19

SOSTEGNI PER L’INSTALLAZIONE Integration Tool CCALT (Design); Integration Tool IT (Design); Integration Tool QCALT (Design); Da realizzare QCALT Installation Tool IT_Insertion Tool CCALT_Insertion Tool

COOLING: DUE SISTEMI DA REALIZZARE AIR COOLING A liquid cooling system is under study by the DA (G. Sensolini). All the cooling pipes (air and liquid) pass through the Beam pipe Support. Air cooling test was made in July using the IP Mockup: Power applied: 40W; Air flow: 300 l/min; ΔT decreasing from 30°C to 25.5 C°; Airflow in order to cool down the inner part of IT; WATER COOLING IT QCALT Cold Airflow Missing: pump, filters..

CONCLUSIONI In questi mesi con KLOE e’ stato possibile il monitoring continuo delle performance di macchina ma anche una presa-dati completa, generalmente di notte e nel weekend Sono stati acquisiti 100 pb-1 di dati unici per lo studio delle interazioni kaone-nucleo, di interesse per Amadeus. Durante la presa-dati si sono rotti 13 radiatori. La sostituzione, non preventivata, di tutti i vecchi radiatori prima della ripartenza e’ necessaria 1) per i lunghi tempi di intervento e 2) i danni al FEE causate dalle perdite di acqua. Tempo di realizzazione di 115 scambiatori: 4 mesi La beam pipe e’ stata estratta una settimana fa L’inizio dell’integrazione degli upgrade sulla BP e’ per meta’ marzo Lo stato e i risultati dei test sui nuovi rivelatori e’ in linea con l’integrazione a meta’ marzo Rimangono alcuni punti dell’integrazione da risolvere: cooling, passaggio cavi e tubi, posizionamento nuovi rack, schermaggio per i quali non e’ ancora chiarissimo il costing 22

KLOE-2 INTEGRATION GANTT In total 33 working days (1,5 months) necessary for integration activity. 22 days devoted to cabling and test of the IT detector. KLOE-2 Integration

A SETTEMBRE... 24

25 D. SC.LNF DATA QUALITY T1 – T5 (ns) crossing time of innermost – outermost ECAL layers for cosmic muons Reconstruction of CM Energy for Bhabha events with the DC

CPT & LORENTZ INVARIANCE TEST 26 KLOE-2 preliminary Δa 0 = (-6.2 ± 8.2 stat ± 3.3 sys ) GeV Δa X = ( 3.3 ± 1.6 stat ± 1.5 sys ) GeV Δa Y = (-0.7 ± 1.3 stat ± 1.5 sys ) GeV Δa Z = (-0.7 ± 1.0 stat ± 0.3 sys ) GeV  Neutral kaon interferometry analysis with π + π - π + π - final state  Search for an interference pattern dependent from direction and/or sidereal time (SME model)  From the simultaneous fit of such interference plots we get

Test of PCB satisfying (optical properties, HV working point, gain) Test with cosmics and final FEE chain in progress One module to the BTF in Feb-March D. SC.LNF27 QCALT: SIPM

D. SC.LNF28 LYSO CRYSTALS Tests in progress Energy resolution = % at 511 keV measured for all crystals with 22 Na source and 1Gs/s digitizer Crystal wrapping: adhesive mylar is chosen of single crystal σ t ~ 450 MeV Performance at high rates to be tested with a pulsed UV-LED with Mylar = 15 pC 22 Na Spectra Q (pC) w/o Mylar = 12 pC SiPM Signal