Inovia & Inovia NOx CIRCUITO GAS CAMERA STAGNA

Slides:



Advertisements
Presentazioni simili
Inovia GAMMA.
Advertisements

Framar biomedica s.r.l. e Belmont Instrument Corp.
Via Nazionale 7 Garessio (Cn), Tel: 0174 Cell: SERENO LUCA.
RinNOVA SOLAR TANK IDRAULICA CALDAIA
RinNOVA Solar Tank CIRCUITO COMANDO CALDAIA
Circuito solare/sanitario
RinNOVA & Inovia CIRCUITI IDRAULICI
RinNOVA RinNOVA IN Inovia CIRCUITO GAS CAMERA STAGNA / APERTA
RinNOVA Cond X & Inovia Cond CIRCUITI IDRAULICI
La macchina da caffe’ espresso
BS.
L’evoluzione della gamma
BINOVA GAMMA.
Rinnova Cond Circuito Comando
Inovia Cond Max IDRAULICA
PARVA Recupera NOX GAMMA
FRANCESCA CIRCUITI COMBUSTIONE E FUMI
SLBD A IDRAULICA. COMPONENTI – –GRUPPO IDRAULICO – –FLUSSOSTATO SANITARIO – –SCAMBIATORE DI CALORE CIRCUITO IDRAULICO.
PARVA Helix IDRAULICA.
Inovia & Inovia NOx CIRCUITI IDRAULICI
NUOVI SCALDABAGNI BIASI A POMPA DI CALORE
BINOVA CIRCUITI IDRAULICI
SCALDABAGNI 11 E 14 L AE.
SCALDABAGNO 13 L SE.
INOVIA & INOVIA NOx
Inovia Cond MAX CIRCUITO COMANDO
Service Inovia Cond MAX CIRCUITO GAS Inovia Cond MAX CIRCUITO GAS.
INOVIA e INOVIA NOx CIRCUITO COMANDO
SLBD S COMANDO.
CIRCUITO GAS BASICA BASICA Plus
MULTIZONE 1 ZONA ALTA TEMPERATURA + 1 ZONA BASSA TEMPERATURA
BINOVA CIRCUITO GAS CAMERA STAGNA CMX CAMERA STAGNA.
PARVA BOILER GAS FUMI.
Service Inovia NOx GAMMA. INOVIA NOx: GAMMA Service PRINCIPALI CARATTERISTICHE –CALDAIA DI RIDOTTE DIMENSIONI (UGUALI PER TUTTE LE POTENZE E PER TUTTE.
SEZIONE COMANDO PARVA BOILER
PARVA Recupera NOX COMANDO
BINOVA GAMMA M297 24CMX.
Inovia Cond HT GAMMA.
Inovia Cond Max GAMMA.
Service RinNOVA GAMMA. RinNOVA: GAMMA Service PRINCIPALI CARATTERISTICHE –CALDAIA DI RIDOTTE DIMENSIONI (UGUALI PER TUTTE LE POTENZE E PER TUTTE LE VERSIONI)
Service PARVA Recupera GAMMA. service PARVA Recupera GAMMA CARATTERISTICHE –CALDAIA MURALE A CONDENSAZIONE A CAMERA STAGNA CON SCAMBIO TERMICO REALIZZATO.
PARVA BOILER CIRCUITI IDRAULICI
SLBD S CIRCUITO GAS.
BINOVA CIRCUITO COMANDO.
PARVA IN INOVIA CIRCUITO COMANDO
RinNOVA SOLAR TANK CIRCUITO GAS
PARVA Helix CIRCUITO GAS
PARVA Recupera CIRCUITO GAS
GAS ARTICA.
PARVA Helix GAMMA.
IMPIANTI TECNOLOGICI – CAP. IV
PARVA Recupera IDRAULICA
PARVA Recupera NOX CIRCUITO GAS
Inovia Cond HT CIRCUITI IDRAULICI
Inovia Cond HT CIRCUITO GAS
Inovia Cond HT CIRCUITO COMANDO
Centralina solare SOL CONTROL dispositivo elettronico programmabile
MODIFICHE & INFORMAZIONI TECNICHE 2015
Service Inovia Cond T260 CIRCUITI IDRAULICI. INOVIA SOLAR TANK- CIRCUITI IDRAULICI Service SCHEMA IDRAULICO.
Inovia IN CIRCUITI IDRAULICI
DEVERO HOTEL (CAVENAGO, MB)
Service Rinnova Cond X GAMMA. Inovia Cond: GAMMA Service PRINCIPALI CARATTERISTICHE –CALDAIA DI RIDOTTE DIMENSIONI (UGUALI PER TUTTE LE POTENZE E PER.
Ossidazione termica COV. Ossidazione COV ex-ante.
TERMODINAMICA.
RinNOVA Cond X Inovia Cond Inovia IN CIRCUITO GAS
Service BINOVA CIRCUITO GAS CAMERA STAGNA / APERTA.
Impianti tecnici della casa
Distribuzione dell’energia elettrica
1 Copyright Riello S.p.A. - confidential Kompakt.
Transcript della presentazione:

Inovia & Inovia NOx CIRCUITO GAS CAMERA STAGNA

VALVOLA GAS MOD. SGV 100 B&P COMPITO CARATTERISTICHE APRIRE E CHIUDERE IL GAS AL BRUCIATORE REGOLARE IL FLUSSO DEL GAS AL BRUCIATORE INTERROMPERE L’AFFLUSSO DEL GAS AL BRUCIATORE IN CASO DI INTERVENTO DELLE SICUREZZE CARATTERISTICHE DIMENSIONI COMPATTE PRIVA DI ORGANI MECCANICI DI TARATURA; A BASSA RUMOROSITA’ MODELLO SGV 100 B&P MODULATORE DA 1 a 37 mbar TEMPERATURA -15°/ + 60° ALIMENTAZIONE DEGLI OPERATORI A 24 Vdc. RESISTENZA EV1 DI 900 OHM RESISTENZA EV2 DI 6500 OHM

FUNZIONE SPAZZACAMINO VERIFICA TARATURA VALVOLA GAS PROCEDURA PER ATTIVARE LA FUNZIONE: ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO CONTEMPORANEAMENTE I TASTI A + B + C FINO A FAR APPARIRE IL PARAMETRO “P01”; PREMERE IL TASTO A FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO “P09”; TRAMITE IL TASTO D IMPOSTARE IL VALORE RIFERITO ALLA POTENZA ALLA QUALE SI VUOL FAR FUNZIONARE LA CALDAIA (vedi tabella); PREMERE IL TASTO C PER MEMORIZZARE IL VALORE IMPOSTATO E PROCEDERE ALLA VERIFICA. P09 = 00 SPAZZACAMINO NON ATTIVO - BRUCIATORE SPENTO P09 = 01 SPAZZACAMINO ATTIVO BRUCIATORE ALLA MINIMA POTENZA P09 = 03 BRUCIATORE ALLA MASSIMA POTENZA P09 = 15 TARATURA VALVOLA GAS La funzione consiste nell’attivazione della caldaia in riscaldamento o in sanitario nel caso di richiesta sanitario per un tempo massimo di 15 minuti. Durante la funzione spazzacamino in riscaldamento viene disattivato il setpoint riscaldamento impostato e forzato al massimo (massima temperatura) ignorando le impostazioni fatte dai tasti o dal comando remoto, il controllo della temperatura viene affidato al sensore di massima temperatura. A D B E C

TARATURE GAS PROCEDURA TARATURA GAS A + B + C PER 10 sec TARATURA PORTATA TERMICA MASSIMA: ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO CONTEMPORANEAMENTE I SEGUENTI TASTI: A + B + C PER 10 sec FINO A FAR APPARIRE SUL DISPLAY LE LETTERE P01 ED IL VALORE DEL MEDESIMO PARAMETRO A D B E C

TARATURE GAS PROCEDURA TARATURA GAS TARATURA PORTATA TERMICA MASSIMA: SCORRERE I PARAMETRI PREMENDO IL TASTO A FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO P09. A D B E C

TARATURE GAS PROCEDURA TARATURA GAS TARATURA PORTATA TERMICA MASSIMA: VARIARE A 15 IL VALORE DEL PARAMETRO P09 PREMENDO IL TASTO D MEMORIZZARE IL VALORE 15 IMPOSTATO PREMENDO IL TASTO C A D B E C

TARATURE GAS PROCEDURA TARATURA GAS TARATURA PORTATA TERMICA MASSIMA: SUL DISPLAY COMPARIRA’ S-H ALTERNATO AL VALORE ELETTRONICO DI POTENZA MASSIMA; VARIARE IL VALORE DEL PARAMETRO AGENDO SUL TASTO A VERIFICARE IL VALORE TARATO TRAMITE UN MANOMETRO DIGITALE SE VIENE SUPERATO IL VALORE DA IMPOSTARE SUL MANOMETRO E’ NECESSARIO USCIRE DALLA PROGRAMMAZIONE E RIPETERE LA PROCEDURA 1 A D B E C

TARATURE GAS PROCEDURA TARATURA GAS TARATURA PORTATA TERMICA MASSIMA: CONFRONTARE LA TARATURA IMPOSTATA CON I VALORI RIPORTATI SUL LIBRETTO CALDAIA. RICORDARSI DI MANTENERE L’ANDAMENTO DI TARATURA IN SALITA; MEMORIZZARE LA TARATURA TENENDO PREMUTO IL TASTO E FINO A CHE IL VALORE NON RIMANE FISSO. A D E B C

TARATURE GAS PROCEDURA TARATURA GAS TARATURA PORTATA TERMICA MINIMA: PER PASSARE ALLA TARATURA MINIMA PREMERE IL TASTO D NEL DISPLAY COMPARIRA’ LA SCRITTA S-L (taratura minima) ALTERNATO AL VALORE ELETTRONICO DI POTENZA MINIMA D A E B C

TARATURE GAS PROCEDURA TARATURA GAS TARATURA PORTATA TERMICA MINIMA: VARIARE IL VALORE DI TARATURA AGENDO SUL TASTO B VERIFICARE IL VALORE TARATO TRAMITE UN MANOMETRO DIGITALE SE VIENE SUPERATO IL VALORE DA IMPOSTARE SUL MANOMETRO E’ NECESSARIO USCIRE DALLA PROGRAMMAZIONE E RIPETERE LA PROCEDURA 1 A D E B C

TARATURE GAS PROCEDURA TARATURA GAS TARATURA PORTATA TERMICA MINIMA: CONFRONTARE LA TARATURA IMPOSTATA CON I VALORI RIPORTATI SUL LIBRETTO CALDAIA. RICORDARSI DI MANTENERE L’ANDAMENTO DI TARATURA IN DISCESA; MEMORIZZARE LA TARATURA PREMENDO IL TASTO E FINO A CHE IL VALORE NON RIMANE FISSO. TOGLIERE ALIMENTAZIONE ELETTRICA PER USCIRE DALLA PROGRAMMAZIONE A D E B C

TARATURE GAS VALORI TARATURA GAS : INOVIA M290.24CM-24 kw Min (mbar) Max (mbar) Metano 2,20 12,80 1,80 11,80 2,00 10,30 Butano 5,60 28,20 4,90 27,90 5,70 27,50 Propano 6,50 36,00 6,40 35,50 7,50 33,10 INOVIA NOx M295.24CM-24 kw M295.28CM-28 kw Min (mbar) Max (mbar) Metano 2,6 13 3,5 15 GPL 8,5 35,5 9,0 35,9

CAMBIO GAS PROCEDURA CAMBIO GAS (1) INOVIA SOSTITUIRE GLI UGGELLI AL BRUCIATORE; CONFIGURARE LA SCHEDA PER IL TIPO DI GAS UTILIZZATO. ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMERE CONTEMPORANEAMENTE I SEGUENTI TASTI: 13, 16 e 17, PER 10 sec; PER IL MODELLO INOVIA; FINO A FAR APPARIRE SUL DISPLAY LE LETTERE P01 ED IL VALORE DEL MEDESIMO PARAMETRO INOVIA

CAMBIO GAS PROCEDURA CAMBIO GAS (2) INOVIA SCORRERE I PARAMETRI PREMENDO IL TASTO: 17, PER IL MODELLO INOVIA; FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO P05. INOVIA

CAMBIO GAS PROCEDURA CAMBIO GAS (3) MODIFICARE IL VALORE DEL PARAMETRO P05 TRAMITE IL TASTO: 17, PER IL MODELLO INOVIA; FINO A FAR APPARIRE IL VALORE IN FUNZIONE AL TIPO DI GAS SEGUENDO LA TABELLA SOTTO RIPORTATA: MEMORIZZARE IL VALORE PREMENDO IL TASTO: 13, PER IL MODELLO INOVIA

UGELLI – ELETTRODI (INOVIA) COLLETTORE GAS CON UGELLI DATI BRUCIATORE 24CM N° 11 RAMPE 28CM N° 14 RAMPE 32CM N° 16 RAMPE UGELLI METANO 24CM = n° 11 X 1,30 28CM = n° 14 X 1,30 32CM = n° 16 x 1,30 UGELLI GPL 24CM= 11 X 0,78 28CM= 14 X 0,77 32CM= 16 X 0,77 ELETTRODO DI ACCENSIONE E RILEVAZIONE COMPITO ELETTRODO DI ACCENSIONE E RILEVAZIONE : INNESCARE LA FIAMMA SULLA MISCELA ARIA GAS ED INVIARE IL SEGNALE DI IONIZZAZIONE ALLA SCHEDA DI ACCENSIONE CARATTERISTICHE CORPO IN CERAMICA ELETTRODO IN KANTAL POSIZIONATO CENTRALMENTE AL BRUCIATORE SCARICA ESEGUITA TRA ELETTRODO E BRUCIATORE

VENTILATORE – VENTURI (INOVIA) COMPITO EVACUARE I PRODOTTI DELLA COMBUSTIONE DATI MODELLO LN NATALINI ALIMENTAZIONE 220 VC.A. POTENZA: 24 KW = 33 W / 63 OHM 28 KW = 47 W / 46 OHM 32 KW = 60 W / 25 OHM VENTURI COMPITO CONTROLLARE LA VELOCITA’ DEI FUMI CREARE UN SEGNALE DI DEPRESSIONE CARATTERISTICHE REALIZZATO IN MATERIALE PLASTICO (RAYTON) RESISTENTE A OLTRE 200°C

PRESSOSTATO FUMI (INOVIA) COMPITO VERIFICA I SEGNALI TRASMESSI DAL VENTURI TRADUCE IN SEGNALE ELETTRICO LA DEPRESSIONE CREATA DAL VENTURI CONSENTE L’ACCENSIONE DEL BRUCIATORE QUANDO C’E’ UNA CORRETTA DEPRESSIONE NON CONSENTE L’ACCENSIONE IN ASSENZA O CON MINIMA DEPRESSIONE IN CASO DI ANOMALIA: E05 DISPLAY CARATTERISTICHE MODELLO HUBA CONTROLL CIRCUITO CONTROLLO FUMI POTENZA CALDAIA PRESSIONE ON PRESSIONE OFF 24 KW 0,49 0,37 28 KW 1,12 0,92 32 KW 1,38 1,25

SISTEMA G.A.R.C. (SOLO INOVIA) CARATTERISTICHE IL SISTEMA GARC E’ COMPOSTO DAI SEGUENTI COMPONENTI: SCHEDA ELETTRONICA; ELETTRODO DI ACCENSIONE/RILEVAZIONE BASA IL SUO FUNZIONAMENTO SUL SEGNALE DI RETROAZIONE (CORRENTE DI IONIZZAZIONE) PROVENIENETE DALL’ELETTRODO DI ACCENSIONE. TALE SEGNALE COMUNICA ALLA SCHEDA SE LA COMBUSTIONE E’ CORRETTA O MENO. IN CASO DI COMBUSTIONE NON CORRETTA, LA SCHEDA ESEGUE DEI CONTROLLI, E IN BASE ALL’ANOMALIA RISCONTRATA, EVIDENZIA I SEGUENTI ERRORI: BLOCCO PER ANOMALIA COMBUSTIONE IN FUNZIONAMENTO;

FORMAZIONE DEGLI OSSIDI DI AZOTO (INOVIA Nox) PER RIDURRE GLI NOX È FONDAMENTALE RIDURRE LA TEMPERATURA DELLA FIAMMA. LE TECNICHE PER OTTENERE UNA COMBUSTIONE A BASSO NOX SONO: SISTEMI DI RAFFREDDAMENTO DELLA FIAMMA ATTRAVERSO IL RAFFREDDAMENTO DEL BRUCIATORE. SISTEMI DI PRE-MISCELAZIONE ARIA /GAS PRIMA DELLA COMBUSTIONE PER RIDURRE L’ARIA SECONDARIA; BRUCIATORI CON FRAZIONAMENTO DELLA FIAMMA. BRUCIATORI CHE TRASMETTONO MAGGIORE CALORE PER IRRAGGIAMENTO (VEDI BRUCIATORI CERAMICI). Metano (CH4) Aria teorica Calore (21% O2 + 79% N2) 1000°C Minima aria secondaria Irraggiamento Ossido di Carbonio (CO) Anidride carbonica (CO2) Vapore acqueo (H2O) Azoto (N2) Ossidi di azoto (NOX) Ossigeno (O2)

BRUCIATORE (INOVIA NOx) COMPITO PREMISCELARE GAS E ARIA PRIMARIA DISTRIBUENDO LA FIAMMA SU AMPIA SUPERFICIE CARATTERISTICHE ACCIAIO INOX 13 o 15 RAMPE A DOPPIO UGELLO (24 o 28 KW) RAFFREDAMENTO AD ACQUA: IL RITORNO RISCALDAMENTO PASSA PER IL CIRCUITO DI IDRAULICO DEL BRUCIATORE RAFFREDDANDO IL TAPPETO E QUINDI LA FIAMMA

BRUCIATORE E COLLETTORE GAS (INOVIA NOx) COLLETTORE GAS CON UGELLI DATI BRUCIATORE 24CM N° 13 RAMPE 28CM N° 15 RAMPE UGELLI METANO 24CM = n° 26 X 0,85 28CM = n° 30 X 0,85 ACCENSIONE RILEVAZIONE ELETTROD0 DI ACCENSIONE E RILEVAZIONE COMPITO ELETTRODO DI ACCENSIONE: INNESCARE LA FIAMMA SULLA MISCELA ARIA GAS ELETTRODO RILEVAZIONE: INVIARE IL SEGNALE DI IONIZZAZIONE ALLA SCHEDA CARATTERISTICHE CORPO IN CERAMICA ELETTRODO IN KANTAL

VENTILATORE – VENTURI (INOVIA NOx) COMPITO EVACUARE I PRODOTTI DELLA COMBUSTIONE DATI MODELLO LN NATALINI ALIMENTAZIONE 220 VC.A. POTENZA: 24 KW = 33 W 28 KW = 39 W VENTURI COMPITO CONTROLLARE LA VELOCITA’ DEI FUMI CREARE UN SEGNALE DI DEPRESSIONE CARATTERISTICHE REALIZZATO IN MATERIALE PLASTICO (RAYTON) RESISTENTE A OLTRE 200°C

PRESSOSTATO FUMI (INOVIA NOx) COMPITO VERIFICA I SEGNALI TRASMESSI DAL VENTURI TRADUCE IN SEGNALE ELETTRICO LA DEPRESSIONE CREATA DAL VENTURI CONSENTE L’ACCENSIONE DEL BRUCIATORE QUANDO C’E’ UNA CORRETTA DEPRESSIONE NON CONSENTE L’ACCENSIONE IN ASSENZA O CON MINIMA DEPRESSIONE CARATTERISTICHE MODELLO HUBA CONTROLL CIRCUITO CONTROLLO FUMI POTENZA CALDAIA PRESSIONE ON PRESSIONE OFF 24 KW 0,55 0,45 28 KW 0,94 0,84