SLBD S CIRCUITO GAS
VALVOLA GAS MODUREG COMPITO CONTROLLA IL FLUSSO DEL GAS AL BRUCIATORE PRINCIPALE MEDIANTE UN COMANDO ELETTRICO AGLI OPERATORI ON-OFF PUO’ ESSERE APERTO O CHIUSO IL PASSAGGIO DEL GAS ATTRAVERSO LA VALVOLA CARATTERISTICHE MODELLO SIEMENS VGU56 GLI OPERATORI ON/OFF DELLA VALVOLA GAS AL LORO INTERNO PRESENTANO UN RADDRIZZATORE PERTANTO NON E’ POSSIBILE CALCOLARNE LA RESISTENZA RESISTENZA MODUREG 85 OHM OPERATORE EV1 OPERATORE EV2
TARATURA VALVOLA GAS METANO PRESSIONE MIN. AL BRUCIATORE 1,5 mBAR PRESSIONE MAX AL BRUCIATORE 13,5 mBAR GPL PRESSIONE MIN. AL BRUCIATORE 3 mBAR PRESSIONE MAX AL BRUCIATORE 30 mBAR
TRASFORMAZIONE GAS PROCEDURA: SOSTITUIRE UGELLI 14 UGELLI DA 1,17 PER GAS CH4 DA 0,74 PER GAS GPL
TRASFORMAZIONE GAS PROCEDURA: SETTARE LA SCHEDA COMANDO a) RUOTARE LA MANOPOLA ON/OFF IN ON PER TRE VOLTE ENTRO DUE SECONDI (fig.1) b) NEL DISPLAY COMPARIRA’ PER DUE SECONDI IL TIPO DI GAS SETTATO IN PRECEDENZA (fig.2 esempio nG = metano) c) RUTOANDO LA MANOPOLA TEMPERATURA SI SELEZIONA IL TIPO DI GAS Ng = metano / LG = GPL PER MEMORIZZARE RUOTARE LA MANOPOLA ON/OFF PER TRE VOLTE ENTRO DUE SECONDI. FIG.1 FIG. 2
VENTILATORE COMPITO ESPELLERE IN MODO FORZATO I PRODOTTI DELLA COMBUSTIONE DATI MODELLO FIME ALIMENTATO A 220 V c.a. RESISTENZA DI CIRCA 45 OHM
VENTURI COMPITO CONTROLLA COSTANTEMENTE LA VELOCITA’ DEI PRODOTTI DI COMBUSTIONE CREA UN SEGNALE DI DEPRESSIONE AL PRESSOSTATO FUMI
PRESSOSTATO FUMI COMPITO TRADUCE IN UN SEGNALE ELETTRICO LA DEPRESSIONE CREATA DAL VENTURI HUBA CONTROL DA’ IL CONSENSO AD ACCEDERE IL BRUCIATORE CON UNA DEPRESSIONE SUPERIORE A 8.5mm C.A. SPEGNE LA FIAMMA SUL BRUCIATORE CON UNA DEPRESSIONE INFERIORE A 7 mm C.A. COLLEGATO ELETTRICAMENTE SOLO IL CONTATTO C-NO