Relè termici elettronici LR9D..

Slides:



Advertisements
Presentazioni simili
MERSEN Sicurezza e Affidabilità per l’ Energia Elettrica
Advertisements

Presentazione Del TAR-Al presetting alesametri TITIESSE SRL
INGRESSI E USCITE.
l’interruttore doppio
IL COORDINAMENTO DELL’ISOLAMENTO
Elementi di sicurezza elettrica
INDAGINI DEL CAMPO DI SPOSTAMENTI INDOTTO DA UNA FONDAZIONE SUPERFICIALE SU SABBIA CON METODI DI ANALISI D’IMMAGINE POLITECNICO DI MILANO FACOLTA’ D’INGEGNERIA.
Life testing di componenti fotonici. Metodologie e strumentazione.
Inizio nuovo lavoro.
L’impianto elettrico nei moli
CENNI DI IMPIANTI ELETTRICI
Riscaldamento dei cavi in cto-cto
Reti elettriche: teoria e applicazioni.
Reti elettriche: teoria e applicazioni.
Prof. Gian Francesco Camatta
La Biblioteca e le sue risorse Catalogo di Ateneo e Opac italiani - Periodici 2-3 marzo 2010.
La Biblioteca e le sue risorse Catalogo di Ateneo e Opac italiani - Periodici 3-4 marzo 2009.
INFORMAZIONI MINIME SULLA PROTEZIONE DELLE CONDUTTURE
TIPI DI IMPIANTI FOTOVOLTAICI
Reti elettriche: teoria e applicazioni.
Parchi Eolici onshore e offshore
04 - MINIMO DOMOTICO E PREDISPOSIZIONI
Glam Nelle foto seguenti la realizzazione di un radioricevitore multigamma a onde corte, a rigenerazione disegnato per sfruttare le multifunzioni di un.
AVVIAMENTO dei MOTORI ASINCRONI TRIFASI
Costruzioni Elettromeccaniche P. Torresan
CORSO DI FORMAZIONE CEI EN (Classificazione CEI 23-3)
DOCWin 3.0.
Costruzioni Elettromeccaniche P. Torresan
Guida all’installazione dei certificati su Internet Explorer e Mozilla Firefox per l’accesso remoto al Donor Manager Softime90 S.n.c.
TR-LC wnw DATI TECNICI MATERIALE: tessuto non tessuto
Sistema elettronico Controllo Idronico 1-2 Livello R&D Engineer SMT – GROUP.
Qualita’ Varieta’ Prezzo La serie Low Cost costituisce la risposta
PROTEZIONE DEI MOTORI ASINCRONI
1 INTERRUTTORI AUTOMATICI MODULARI SERIE STRUTTURA OFFERTA Gamma compattaGamma standard PROTEZIONE CIRCUITI MTC MT PROTEZIONE DIFFERENZIALE MDC.
Interruttore differenziale
REGIONE MARCHE - GABINETTO DEL PRESIDENTE - P. F
Potenziometri I trasduttori lineari di posizione serie PL sono potenziometri estremamente robusti per applicazioni industriali. Le loro caratteristiche.
INTERRUTTORI AUTOMATICI DI BASSA TENSIONE.
SISTEMA AUTOMATICO COMANDO TAPPARELLE
TERMORESISTENZE E TERMISTORI
Suddivisione di uno Schema Elettrico:
Ventilconvettore Serie FFC
CORSO SULLA PROTEZIONE DELLE CONDUTTURE CONTRO LE SOVRACORRENTI
Altivar 312 intuitivo&comunicativo
Altivar 31 Compact TOOL SCELTA COMPONENTI
Compatto&performante!
October, 2009 VM1: innovazione nella tecnologia di MT Interruttore in vuoto con attuatore magnetico Presentazione 1VCP – Rev. C, it – Presentation.
Rinnova Cond Gamma.
Service Inovia NOx GAMMA. INOVIA NOx: GAMMA Service PRINCIPALI CARATTERISTICHE –CALDAIA DI RIDOTTE DIMENSIONI (UGUALI PER TUTTE LE POTENZE E PER TUTTE.
SHS2 Interruttori di manovra/sezionatori isolati in Gas
1VCP – Rev. A – IT – Presentation –
Inovia Cond Max GAMMA.
Service RinNOVA GAMMA. RinNOVA: GAMMA Service PRINCIPALI CARATTERISTICHE –CALDAIA DI RIDOTTE DIMENSIONI (UGUALI PER TUTTE LE POTENZE E PER TUTTE LE VERSIONI)
RinNOVA SOLAR TANK CIRCUITO GAS
Sistemi elettrici di potenza
DM 12 DICEMBRE 2012 REGOLA TECNICA DI PREVENZIONE INCENDI PER GLI IMPIANTI DI PROTEZIONE ATTIVA CONTRO L'INCENDIO INSTALLATI NELLE ATTIVITÀ SOGGETTE AI.
Apparecchi di manovra: classificazione
Impianto con Comando Sequenziale
La protezione elettrica
Siemens Automation Cooperates with Education
Service Rinnova Cond X GAMMA. Inovia Cond: GAMMA Service PRINCIPALI CARATTERISTICHE –CALDAIA DI RIDOTTE DIMENSIONI (UGUALI PER TUTTE LE POTENZE E PER.
Service RinNOVA SOLAR TANK GAMMA. RinNOVA SOLAR TANK: GAMMA Service PRINCIPALI CARATTERISTICHE SISTEMA DA INTERNO PER PRODUZIONE DI ACQUA CALDA SANITARIA.
Sistema di Riferimento Veneto per la Sicurezza nelle Scuole
PROGRAMMA PRODOTTI 2010.
Campi Elettromagnetici Monitoraggio a lungo termine e interpretazione dei dati 25 giugno 2008 Mirco Scotto.
1 Copyright Riello S.p.A. - confidential Kompakt.
A SSOCIAZIONE S PORTIVA D ILETTANTISTICA C RONOMETRISTI DELLA PROVINCIA DI B OLZANO Z EITNEHMER A MATEURSPORTVEREIN DER PROVINZ B OZEN a cura di Sante.
Una soluzione, molte applicazioni Integrated Electronic Solution PowerSupply Flex.
Programma delle lezioni Generalità sugli impianti(1) √ Generalità sugli impianti(1) √ Produzione dell’energia elettrica(1) √ Produzione dell’energia elettrica(1)
Guido Monaco Impianto di illuminazione di tre lampade (in serie) comandate da un punto (Interruttore)
Transcript della presentazione:

Relè termici elettronici LR9D.. Select “host meeting” and “automatically accept calls” in Netmeeting Share desktop with this showing so people can dial in if they don’t have the number handy What is this document? MGT-03 is a mandatory PMP document. It is required for the OPEN stage gate review. This document consolidates the opening conditions of the project. It expresses the decision to achieve a specific set of objectives before a given deadline. Specifies the elements used by management to justify the decision to OPEN a project. Marks the official beginning of the project, responsibility agreement by the project manager, and the start of the expenditure recording.. This document is written prior to the Formal Stage Gate Review and once approved constitutes completion of the Phase. This document is considered to be a summary or synthesis of all work done to meet the criteria to Pass the stage gate. In most cases more detailed documentation will have captured this work and this PMP deliverable document collects and summarizes the salient points of these other documents. This PMP deliverable document is to be stored in the Genesis Project Data Management system. This document constitute a template. It is requested that you do not change these section headings. Following each heading you can place your cursor and enter your information. Insert as many lines, page breaks…etc as are required to complete that section. You are not limited to the initial space shown in the template. Pictures and diagrams may also be added inside these sections. The notes section this template is guide on how to complete the template, document. The guide is only for instruction purposes; project information needs to be added to the template and not the guide. This presentation has been reviewed for global use. It is the intent that this review last approximately 45 minutes. The template should be used as presented to create consistency.

Contesto Totale relè termici bimetallo LRD / LR2K elettronici LR97 LR9D / LR9F LT47 elettronico TeSys T

Contesto Relè termici serie D fino a 150 A Da 0,10 a 32 A classe 5–10-20-30 regolabile montaggio diretto sotto i contattori da 9 a 38 A Da 22 a 110 A classe 5-10-20-30 regolabile montaggio separato LR97 LT47 Da 60a 150 A classe 10 o 20 montaggio diretto sotto i contattori da 115 a 150 A Da 0,10 a 140 A classe 10 o 20 Montaggio diretto sotto i contattori da 9 a 95 A 0,10A 60 A 110 A 150 A

Caratteristiche generali 4 Caratteristiche generali Certificationi e Standards Caratteristiche Larghezza 45 mm (fino a 32 A) autoalimentati Stesso look TeSys 10 Selezione della classe 30 5 20 IEC Certification CE Marking Indicazione TRIP 1 2 3 5 4 5 campi di taratura tasto di test sul frontale Bottone di stop sul frontale UL Listing CSA Certification Accessorio per montaggio separato (0.1-150 Amps) Montaggio diretto fino a 32 A CCC Certification

Caratteristiche generali Classe di intervento selezionabile 5-10-20-30 Montaggio diretto sotto I contattori Autoalimentazione Non necessita di alimentazione esterna Potenziometro per la regolazione della taratura Tasto multifunzione: reset e stop (AO-HO) Reset manuale o automatico (H-A) Fessura per il test Fessura per la visualizzazione del trip

Caratteristiche generali Classe di intervento selezionabile 5-10-20-30 Tasto multifunzione: reset e stop (AO-HO) Reset manuale o automatico (H-A) Ampio campo di taratura 22 – 110 A Fessura per la visualizzazione del trip Fessura per il test

Caratteristiche generali

Caratteristiche generali 8 Last two points for “Can Do” pertain to North America and OEM’s who export to North America Caratteristiche generali Si può fare Protezione dei motori IE3 Coordinamento tipo 2 con fusibilil e interruttori automatici Elevato potere di interruzione ( 65 KA ) già in coordinamento tipo 1 Non si può fare Protezione guasti verso terra Reset remoto elettrico

Gamma 5 tipi di relè ( da 0,10 a 110 A ) 4 per montaggio diretto sotto i contattori da 9 a 38 A LR9D01 0,10 – 0,5 A LR9D02 0,4 – 2 A LR9D08 1,6 – 8 A LR9D32 6,4 – 32 A LAD7B205 accessorio per montaggio separato 1 per montaggio separato LR9D110S 22 – 110 A

Gamma CHIARIFICAZIONE SUPPORTI LAD7B106 LAD7B105 LAD7B205 per i relè bimetallo classe 10 ( LRD01-LRD35 e LR3D01-LR3D35 ) LAD7B105 per gli attuali relè bimetallo classe 20 ( LRD1508-LRD1532 ) LAD7B205 per i nuovi relè elettronici ( LR9D01-LR9D32 ) per i nuovi relè a bimetallo classe 20 ( ex LRD15.. )

LR9D verso LR97 e LT47 LT47 LR97 LR9D Descrizione 1111 LR9D verso LR97 e LT47 LT47 LR97 LR9D Descrizione Relè di sovracorrente Relè termico Protezione termica NO SI Curva I2T Trip Number of CTs 2 3 Autoalimentazione MFLC range 1:10 1:5 Larghezza ( fino a 32 A ) 71 mm 45 mm

LR9D verso LRD LRD LR9D Temperatura Da compensare insensibile 1212 LR9D verso LRD LRD LR9D Temperatura Da compensare insensibile MFLC range 1:1,5 1:5 Classe di intervento 10 o 20 5, 10, 20, 30 regolabile Autoalimentazione SI Connessioni Viti , molla , occhiello Viti Montaggio separato Larghezza ( fino a 32 A ) 45 mm Reset auto/manual Fisso Regolabile