Scaricare la presentazione
La presentazione è in caricamento. Aspetta per favore
1
TOPEM Meetings Catania, 1.12.2010
Misure di temporizzazione con LYSO e PMT Burle 8850 Roma, PMT R9880U-110 sba Catania, TITLE: A light cluster counting drift chamber as central tracker for the ILC experiments. ABSTRACT: Experiments at the ILC will require a level of precision for momentum measurements, which demands unprecedented detector performance for tracking, deriving from the ILC physics program.A momentum resolution of σp/p2~4 x 10−5 (GeV/c)−1is required, e.g. for typical benchmark processes wherethe Higgs mass is to be measured through the associate production and decay of a Z into two muons with 150 MeV/c2 resolution.A cluster counting drift chamber,owing to its outstanding features in terms ofmaterial budget (improving multiple scattering),position resolution at the 50 um level,particle ID capabilities of few percent,easy construction,is shown to potentially be a premium choicein comparison to other technologies under study:a TPC with sophisticated high-precision end planes, and a silicon strip tracker. R. De Leo[1], M. Mastromarco[1], R. Perrino[2] [1] Università e INFN Bari [2] INFN Lecce
2
COPPIE FOTOTUBI DISPONIBILI
R9880U sba / R7600U uba CRISTALLI DISPONIBILI LYSO dim. [mm] 1 pezzo 10 x 10 x 10 (Burle 8850) 2 pezzi 5 x 3 x 3 (R9880U-110)
3
Outline Set-up sperimentale Spettri di carica e carica-tempo
Confronto fra varie sorgenti di calibrazione Calibrazione in energia Risoluzione in energia Risoluzione in tempo TOPEM Meeting Roma,
4
Set-up sperimentale LYSO 10x10x10 & Burle 8850 FIFO CFD PMT 8850 gamma
dB attenuator + delay CFD Ortec935 delay Linear input GATE PMT 8850 Charge ADC gamma source STOP Linear input LYSO 10x10x10 mm3 LYSO 10x10x10 & Burle 8850 Coincidence unit Gate generator TDC 25 ps/chan START PMT 8850 STOP CFD Ortec935 delay FIFO dB attenuator + delay NIM CAMAC Data Storage
5
Scatter plot ADC-left versus ADC-right
1275 KeV Scatter plot ADC-left versus ADC-right 511 KeV Na22
6
Scatter plot ADC-left versus ADC-right
662 KeV 1333 KeV 1173 KeV Cs137 Co60
7
Sommario varie sorgenti (ADC L+R)
Na22 Cs137 Co60 Internal radioactivity
8
Analisi in energia Estrazione parametri da picchi di calibrazione: centroide e sigma per stima risoluzione energia 511 keV 1275 keV /E= 5 % /E= 2 % Na22
9
Analisi energia Cs137 e Co60 /E= 5 % /E= 2 % 662 keV 1173, 1333 keV Cs137 Co60
10
E/E NPE Risoluzione in energia Stima del numero dei fotoelettroni
E/E = enf/sqrt(NPE) enf=1.2 E/E NPE
11
CFD adjusted to minimize time-charge effects
Cs137 Na22 Co60 1173 KeV 1275 KeV 1333 KeV 662 KeV 511 KeV TDC spectrum TDC spectrum TDC spectrum CFD adjusted to minimize time-charge effects
12
Time resolution vs. energy t = A ⊕ B/E1/2 baseline A = 233 ps
Contributi baseline nostro set-up: A = lyso ⊕ elx ⊕ 2 pmt t = A ⊕ B/E1/2 lyso~100 ps /√Npe/ √12 elx ~ 25 ps 2 pmt è predominante Burle8850 RT=2.1 ns TT=31 ns baseline A = 233 ps source energy half seen by each PMT
13
PMT vedono ~1/2 luce prodotta in fotopicco 511KeV.
Nuove misure in set-up modificato + PMT più veloci e con minor TTS Vecchia MISURA Burle8850 RT=2.1 ns TT=31 ns TTS=? LYSO 10 x 10 x 10 mm3 ~ 2000 PE/MeV PMT vedono entrambi tutta la luce prodotta in fotopicco 511 KeV. R9880U-110 RT=0.57 ns, TT=2.7 ns 2 x LYSO 3 x 3 x 5 mm3 Nuova MISURA
14
Set-up sperimentale Set-up sperimentale Fast Ampl. x10 LE PMT gamma
dB attenuator + delay LE delay Linear input GATE PMT Charge ADC gamma source STOP Linear input LYSO 3x3x5 mm3 Coincidence unit Gate generator TDC 25 ps/chan START STOP PMT LE delay Set-up sperimentale dB attenuator + delay FastAmpl.x10 NIM CAMAC Data Storage
15
= 4.9 ch = 122 ps FWHM = 288 ps
16
Internal radioactivity
2 crystals in coincidence with no source
17
Misure CT Internal radioactivity: 3 gamma lines and a beta spectrum
sum of the 3 gamma lines 22 Na source
Presentazioni simili
© 2024 SlidePlayer.it Inc.
All rights reserved.