Ion Electron Emission Microscope

Slides:



Advertisements
Presentazioni simili
Trieste, 26 novembre © 2005 – Renato Lukač Using OSS in Slovenian High Schools doc. dr. Renato Lukač LinuxDay Trieste.
Advertisements

Centro Internazionale per gli Antiparassitari e la Prevenzione Sanitaria Azienda Ospedaliera Luigi Sacco - Milano WP4: Cumulative Assessment Group refinement.
P. Sarti, C. Abbondanza, S. Montaguti, M. Negusini, L. Vittuari
L’esperienza di un valutatore nell’ambito del VII FP Valter Sergo
Cache Memory Prof. G. Nicosia University of Catania
Staf di sperimentatori:Primo Ighina
Teoria e Tecniche del Riconoscimento
16/04/2009Giornata Illustrativa Progetti IMM-CNR 1 RRoBAT R obust Ro botics B ased on A udio T echnologies Ore 10:00 IMM-CNR Sala di Riunioni 16 Aprile.
Parametri Acustici (ISO 3382)
1 Teaching Cloud Computing and Windows Azure in Academia Domenico Talia UNIVERSITA DELLA CALABRIA & ICAR-CNR Italy Faculty Days 2010.
A. Oppio, S. Mattia, A. Pandolfi, M. Ghellere ERES Conference 2010 Università Commerciale Luigi Bocconi Milan, june 2010 A Multidimensional and Participatory.
DG Ricerca Ambientale e Sviluppo FIRMS' FUNDING SCHEMES AND ENVIRONMENTAL PURPOSES IN THE EU STRUCTURAL FUNDS (Monitoring of environmental firms funding.
A direct measurement of the mirror thermal noise Paolo Amico Università degli studi di Perugia and INFN sez. Perugia ILIAS - GW Meeting, May 2004.
Udine 1 Udine – Richieste Attivamente coinvolti totali 3FTE M.P.Giordani, P.Palestri, L.Selmi A.Micelli (dottorando) A.Cristofoli (laureando.
A. Nuzzo U.O. di Oncologia Medica ospedale Renzetti di Lanciano (CH)
G.M. Tino, LNF, 16/2/2005 Orologi e interferometri atomici nuovi sensori ad atomi ultrafreddi per esperimenti di fisica fondamentale e applicazioni in.
1 Benvenuti nei LNF. Frascati National Labs (LNF) Lab footprint m 2 Total Staff 368 Researchers 98 Technologist/ Engineers 62 Technicians 167.
Siena, settembre 2005 (III) 1 Theory of electron transport in semiconductor materials and structures Carlo Jacoboni INFM-CNR National Research Center on.
Siena, settembre 2005 (II) 1 Theory of electron transport in semiconductor materials and structures Carlo Jacoboni INFM-CNR National Research Center on.
1 A neural approach to the analysis of CHIMERA experimental data CHIMERA Collaboration S.Aiello 1, M. Alderighi 2,3, A.Anzalone 4, M.Bartolucci 5, G.Cardella.
CSN giugno Comunicazioni Riunione R-ECFA ai LNF 21&22 maggio; buona impressione data dallEnte. Follow-up? Giornata PT ai LNGS 3&4.
Biometry to enhance smart card security (MOC using TOC protocol)
Camera CCD in sviluppo allXUVLab per un esperimento su razzo, precursore dellesperimento UVC del Solar Orbiter Compact (72mm x 72mm x 50mm) Lightweight.
Infrastruttura & Competenze ICT ENEA
Avis Contact Centres Review
PLANCK LFI N. Mandolesi Consorzio PLANCK-LFI Incontro con Prof. P. Benvenuti IASF/CNR - Sez. di Bologna, Gennaio 2004.
Dafinei_Otranto2012_Lesson-2 Ioan Dafinei INFN Sezione di Roma, ITALY OTRANTO Settembre 2012 XXIV SEMINARIO NAZIONALE Di FISICA NUCLEARE E SUBNUCLEARE.
2000 Prentice Hall, Inc. All rights reserved. 1 Capitolo 3 - Functions Outline 3.1Introduction 3.2Program Components in C++ 3.3Math Library Functions 3.4Functions.
1 Astroparticle Physics in Space Claudia Cecchi Dipartimento di Fisica e Sezione INFN, Perugia Workshop Nazionale La Scienza e la Tecnologia sulla Stazione.
Laurea specialistica in Scienza e Ingegneria dei Materiali
Nanoscience Laboratory Silicon nanophotonics Metamaterials Nanobiotechnologies, antioxidants and human health Few lab members.
WP 10 – Applicazioni Astrofisica – stato Leopoldo Benacchio INAF Osservatorio Astronomico di Padova Pisa maggio 03.
Applicazioni dell'Elettronica basata sul Diamante _________________________________________ Arnaldo Galbiati SOLARIS PHOTONICS Alkaline Solar Cells and.
Rivelatori a stato solido basati su diamante per applicazioni su raggi X Buongiorno a tutti !!! Scopo di questa presentazione e mostrarvi alcuni dei.
ATE / 31 Lezione 3 i sistemi automatici di misurazione - gli ATE.
Introduzione: lequazione di stato (EoS) Particelle prodotte in collisioni ad energie relativistiche (1-2 AGeV) Pioni e kaoni come osservabili per lEoS.
Il documento non deve essere riprodotto, modificato, adattato, pubblicato, tradotto in qualsiasi forma sostanziale, in tutto o in parte, né divulgato a.
FIRB projectInnovative Magnetic Materials Structured in Nanoscopic Scale Tematica T1 materiali nanogranulari Unità partner di Napoli L. Lanotte, C. Luponio,
Onde di spin in film epitassiali ultrasottili ed in campioni patterned FIRB Parma, 10 ott G. Carlotti, G. Gubbiotti, M. Madami, G. Socino, S. Tacchi.
Istituto di Fisica dello Spazio Interplanetario M.F. Marcucci SAIT Teramo 4-8 maggio 2008 Nuove conoscenze sulla riconnessione magnetica dai dati della.
LHCf Status Report Measurement of Photons and Neutral Pions in the Very Forward Region of LHC Oscar Adriani INFN Sezione di Firenze - Dipartimento di Fisica.
A B C Fascio continuo Energia GeV 200 A, polarizzazione 75-85% 1499 MHz Distribuzione simultanea in 3 sale.
S. Bolognesi (1) from CMS A. Di Simone (2) from ATLAS 1 Università di Torino ed INFN Torino 2 Università di Roma Tor Vergata ed INFN Roma 2 V workshop.
7 N. Dinu, E. Fiandrini and L. Fano' Overview of the electrical characterization of AMS/CMS silicon microstrip detectors, Nota INFN AE-06/1.
Il Trigger di AMS-02 Stato dellarte. Trigger: Stato dellarte I livelli di trigger dellesperimento: -Fast trigger:FTC (particella carica attraversa il.
Ettore Vittone: Dip. Fisica Sperimentale, Università di Torino; A.A Fisica dei Dispositivi Elettronici e Sensori; Laurea in Fisica; Fisica Stato.
PASTIS CNRSM, Brindisi – Italy Area Materiali e Processi per lAgroindustria Università degli Studi di Foggia, Italy Istituto di Produzioni e Preparazioni.
Ischia, giugno 2006Riunione Annuale GE 2006 Exploiting the Body Effect to Improve Analog CMOS Circuit Performances *P. Monsurrò, **S. Pennisi, *G.
IMM ISTITUTO PER LA MICROELETTRONICA E MICROSISTEMI (IMM) – CONSIGLIO NAZIONALE DELLE RICERCHE (CNR) UNITA DI CATANIA Dispositivi di potenza ed iperfrequenza.
Microsoft Kinect IR PATTERN PROJECTOR IR CAMERA RGB CAMERA.
1 6. Astronomia Gamma Corso Astrofisica delle particelle Prof. Maurizio Spurio Università di Bologna. A.a. 2011/12.
Motor Sizing.
embryo GPS dish (Rieger et al., 2007) Avvicinamento degli embrioni rispetto a micro gocce tradizionali e minore superficie.
MILANO Single step D=400mm, f=40°Diag From a message of Levacher about next step thermal analysis for the baffle can be allocated a space of.
Laboratorio in banda X V. Fioretti - INAF/IASF Bologna The Simbol-X mission and the background rejection Corso di Strumentazione per l'Astrofisica 21/05/08.
Federazione Nazionale Commercio Macchine Cantiermacchine Cogena Intemac Unicea Unimot ASSOCIAZIONE ITALIANA PER LA PROMOZIONE DELLA COGENERAZIONE.
BioSInt Unit Superfici ed Interfacce biofunzionali Cecilia Pederzolli
CUORE (Cryogenic Underground Osservatory for Rare Events) and CUORICINO For searches on neutrinoless decay WIMPs and axions interactions and on rare nuclear.
UG40 Energy Saving & Twin Cool units Functioning and Adjustment
Guida alla compilazione del Piano di Studi Curricula Sistemi per l’Automazione Automation Engineering.
Lezione n°27 Università degli Studi Roma Tre – Dipartimento di Ingegneria Corso di Teoria e Progetto di Ponti – A/A Dott. Ing. Fabrizio Paolacci.
Neutron Instrumentation Carla Andreani Universita’ degli Studi di Roma Tor Vergata-Dip. Fisica e Centro NAST.
Min mAU mAU min min
Scenario e Prospettive della Planetologia Italiana
1 Acceleratori e Reattori Nucleari Saverio Altieri Dipartimento di Fisica Università degli Studi - Pavia
Michele Iacovacci (Napoli),
Gigi Cosentino - LNL 20 ottobre 2016
Preliminary results of DESY drift chambers efficiency test
Information In March we decided to start to work on this topic in strong collaboration with Roma 1 group: Ferrante (50-70%), Braccini (50-70%), Torre (100%),
Transcript della presentazione:

Ion Electron Emission Microscope IEEM Lecce 24/09/2003 Draft 11/09 Ion Electron Emission Microscope responsabile nazionale: Jeff Wyss INFN/Pisa Gruppo V “1 picture = 1k words” Live chip electrostatic lenses  microscope 2D electron sensor Secondary electrons e e e ion e bulk active volumes

IEEM Microscopio ASSIALE ad emissione di elettroni per impatto ionico Sezioni INFN: Pisa, Padova, Roma2 Linea di ricerca: Single Event Effects (SEE) indotti da ioni energetici in dispositivi e sistemi microelettronici per applicazioni spaziali, di fisica delle alte energie, ed industriali. Laboratorio e facility: Legnaro, Tandem XTU da 15MV, linea di irraggiamento con ioni SIRAD (Li-Au). Processo fisico: correlazione su scala micrometrica tra i punti di impatto ionico e SEE indotti in vari dispositivi (ASIC, commerciali, strutture di test) mediante l’uso di un microscopio assiale ad emissione di elettroni secondari da impatto ionico normale. Durata e preventivo globale: due anni, 130 kEuro 2004: costruzione, installazione IEEM con sistema di test SDRAM sulla linea SIRAD, risultati preliminari; Preventivo 2004 (kEuro): 25 (PI) + 48 (PD) + 20 (RM2) = 93 2005: messa a punto e presa dati.

What is SIRAD SIRAD is the acronym for SIlicon and RADiation. The purpose of the SIRAD facility is: "investigate radiation effects on silicon detectors, micro-electronic devices and systems in radiation hostile environments". - Total Dose Effects: cumulative effects due to ionization (dose). - Bulk Effects: cumulative effects due to displacement damage (fluence). - Single Event Effects: instantaneous effects resulting from the strike of a single energetic particle (probability, cross-section). - High Energy Physics experiments (CDF, CMS,...). - Space missions of scientific satellites (GLAST, AGILE, PAMELA,...) silicon detectors (CDF, CMS, SMART) ASIC microelectronics (CMS, GLAST, AGILE) commercial off the shelf microelectronics (FPGA, FLASH, SDRAM, power devices) test structures (physics of ultra-thin oxide rupture)

The SIRAD beam line (protons and ions) Accelerator: - Tandem Van de Graaff; - 15 MV maximum voltage; - two strippers.  ions from H (30 MeV) to Au (300 MeV) NOTE: The AXIAL IEEM will be installed downstream of SIRAD chamber to COEXIST with the intense and successful SIRAD program.

Ion beams available at SIRAD • Ion species from 1H (23-30 MeV) up to 197Au (1.4 MeV/a.m.u.) • LET from 0.02 MeVcm2/mg (1H) up to 81.7 MeVcm2/mg (197Au)

Institutions and industrial partners participating to SIRAD The experiments are performed in collaboration with more than 80 scientists and researchers from 26 Italian and foreign institutions and industrial partners [1] INFN, Laboratori Nazionali di Legnaro [2] INFN, Sezione di Padova [3] INFN, Sezione di Perugia [4] INFN, Sezione di Pisa [5] INFN, Sezione di Trieste [6] Dipartimento di Fisica, Università di Padova [7] Dipartimento di Fisica, Università di Perugia [8] Dipartimento di Fisica, Università di Trieste [9] Dipartimento di Automatica e Informatica, Politecnico di Torino [10] Dipartimento di Elettronica ed Informatica, Università di Padova [11] Dipartimento di Ingegneria, Università di Ferrara [12] Dipartimento di Meccanica, Struttura, Ambiente e Territorio, Università di Cassino [13] Istituto di Astrofisica Spaziale e Fisica Cosmica (IASF), Sezione di Roma. [14] Istituto di Astrofisicia Spaziale e Fisica Cosmica (IASF), Sezione di Bologna [15] Dipartimento di Ingegneria Elettronica, Università Autonoma di Barcellona, Spagna [16] ENSERG-INPG, Grenoble (France) [17] GSI, Darmstadt (Germany) [18] Institut de Microelectrònica de Barcelona (IMB), CNM-CSIC, Barcelona, Spain [19] Lawrence Berkeley National Laboratory (LBL), Berkeley, USA [20] LETI-CEA, Grenoble (France) [21] Institute of Physics, Academia Sinica, Taiwan [22] SCIPP-University of California at Santa Cruz (UCSC), Santa Cruz, USA [23] Aurelia Microelettronica, Navacchio Cascina (PI) [24] Center for Advanced Research in Space Optics (CARSO), Area Science Park, Trieste [25] Istituto di Ricerca Trentino (IRST), Trento [26] ST Microelectronics, Agrate Brianza (MI)  INFN A SIRAD 5 anni di attivita` piu` di 30 pubblicazioni nel 2002-2003 (IEEE, NIM A ann B, Microelectronics Reliability, conferenze NREC, RADCES, ICNMTA IBA,...). Circa 15 articoli sottomessi nel 2003.

Beam time allocation at SIRAD in 2002 (26 days) Single Event Effects: 71% An IEEM would be COOL!

Single Event Effects (SEE) A single incident particle may produce directly or indirectly enough energy in the form of ionization to cause a single macroscopic (anomalous) effect in a polarized device. e.g. or NEUTRON A nuclear spallation reaction induced by protons and neutrons. Top: cascade stage in which fast secondaries emerge in the forward direction. Middle: evaporation stage in which secondary protons, neutrons, deuterons and alphas particles emerge isotropically. Bottom: recoil stage in which the residual fragment of the target nucleus emerges with the momentum gained in the earlier stage. SEE effects are induced in a live electronic device if the ionization induced in the sensitive volume of the device by a primary ionizing particle or by secondary particles or by a recoiling nucleus is higher than some characteristic SEE threshold value.

SEE-OLOGY For a given radiation environment (HEP experimental hall, orbit in outer space mission, solar activity) the mechanisms of an SEE and the PROBABILITY of it occurring are device and technology dependent. -destructive events: Single Event Burnout (SEB) in power DMOS transistor Single Event Snapback (SES) in MOSFET Single Event Gate Rupture (SEGR) in DMOS transistor Single Event Latch-up (SEL) in CMOS technologies -non destructive events: Single Event Drain Current Collapse (SEDC2) Single Event Upset (SEU) Single Event Disturb (SED) Single Event Transient (SET) Single Event Functional Interrupt (SEFI)

Radiation Effects: SEE (SEU+SEL) (SIRAD) Radiation Effects: SEE (SEU+SEL) Expected rates are low Importance of SEE: SEU: data corruption data stored in register cells are altered by induced charge SEU hardened registers SEL: potentially destructive inherent p-n-p-n parasitic structures in CMOS can be activated by injected charge: short-circuit polyswitches in LAT, but… SEL sensitive parasite structure GLAST Collaboration Meeting - Rome 15-18 September, 2003

SEE cross-sections SIRAD broad beam experiments The cross section () for Single Event Effects is  = RSEE /  RSEE: Rate (counts/s) of SEE observed : uniform flux 102105 ions cm-2s-1 (fiducial area 2cm-by-2cm) typical measured and ideal SEU cross section curves per bit, device, etc. () In silicon a LET of 97 MeV-cm2/mg corresponds to charge deposition per unit path length of 1pC/m. NOTE factor ~100: it is handy for conversion. SAT WEIBULL FIT = sat{1-exp[-(L-Lth)/W]S} sat: saturation value Lth: threshold LET value W and s are fitting parameters Lthreshold ()

SIRAD data: SEE effects in Application Specific-ICs broad beam on chip Single Event Upset (SEU) cross section for the pipeline of the APV25 chip for CMS. Solid line is a multiple Weibull prediction based on simulations, but direct microscopic evidence would be more compelling.

sensitivity micro-map CMOS 256K SRAM unit cell SEU simulation Davinci 3D-simulation, P.E.Dodd et al., IEEE Trans.Nucl.Sci. Vol 48 pp1893-1903, Dec. 2001 Simulations were performed for ion strikes incident every 0.5 m throughout the unit cell. New sensitive area for LET > 30 MeV-cm2/mg Evolution of the SEU sensitive area as a function of the ion LET, including initially only the reverse biased NMOS drain and then also the reverse biased PMOS drain.

simulazioni VS microscopia Le simulazioni dei dispositivi sono cruciali per: la comprensione dei meccanismi alla base di SEE; individuazione di tecniche di sopravvivenza. La microscopia serve a: generare dati utili per validare modelli dei dispositivi; diagnosticare problemi residui difficilmente simulabili (e.g. a livello di sistema); certificare le prestazioni di un dispositivo in un ambiente radioattivo.

microbeams and IEEMs Traditionally micro-maps are performed at micro-beam facilities. In the nuclear microprobe technique a micro-beam spot is systematically moved with micro-precision across a device to build up a sensitivity map. Lateral resolution: 0.31m. In the IEEM technique (B.L.Doyle, SANDIA, 1999), instead of micro-focusing the beam, one reconstructs the impact point of the ion! Lateral resolution: 0.61m. With an IEEM the SIRAD beam-line would acquire SEE micro-mapping capabilities with a non-invasive upgrade that would not interfere with the normal successful SIRAD activity. NOTE: The AXIAL IEEM will be installed downstream of the SIRAD chamber. The IEEM of SIRAD would be the first of its type with its opto-electronic approach allows for upgrades of the sensors; operational flexibility.

nuclear microprobe VS IEEM Nuclear Microprobe Analysis Ion Electron Emission Microscopy Ion beam 2D electron detector at focal plane of electron optics object slit (Xhit,Yhit) Nuclear Microprobe: focusing (e.g. triplet) and scanning system  secondary electrons Ion beam electron optics (Xbeam,Ybeam) rastering pattern channeltron hit confirmation by secondary electrons coating analysis of signal target analysis of signal target Resolution on target determined by beam optics: spot size and positioning. Difficult to micro-focus all SIRAD ions; e.g. rigidity of a 300 MeV Au+25 ion is 1.40 T-m, 1.7 times more than 95 MeV C+6 ion. Would require disruptive and expensive upgrade of SIRAD and of controls of Tandem Optics! Resolution on target: lateral size of field of view divided by linear line pair resolution of sensor. analysis: SEE mapping, Ion Beam Induced Charge Collection, Time Resolved IBICC,...

Schematic of the axial ( = 0o) IEEM of SIRAD UV lamp (PEEM) SIRAD contrast diaphragm I I lens photon sensor The ion impact position on the target is determined by “imaging” the position from which secondary electrons are emitted. A contrast diaphragm with a 300m diameter aperture controls the aberrations: the intrinsic resolution of the IEEM on the target is of the order of 0.6m over a 250m field of view. This startup resolution must be degraded as little as possible by the sensors.

progetto: IEEM assiale Opto-elettronico per SIRAD and phosphor Based on commercial electrostatic lenses for photon electron emission microscopy (PEEM). Nella configurazione assiale il fascio di ioni incide normalmente sul bersaglio e gli elettroni secondari emessi dagli impatti ionici sono trasportati dal microscopio verso un Micro Channel Plate anulare posto nel piano focale. Il segnale elettronico viene quindi convertito in uno luminoso da un fosforo veloce. Il segnale luminoso viene quindi messo a fuoco su di un intensificatore di immagine accoppiato ad un PSD che ricostruisce il punto d’impatto degli ioni con risoluzioni laterali efficaci di almeno 400 punti lineari e sostiene un massino ion impact rate di 104 Hz. Gli impatti vanno quindi correlati con gli SEE nel dispositivo sotto test per costruire mappe di sensibilita`.

lavoro svolto, situazione attuale, richieste al GrpV Photon-EEM con fondi UNIVERSITA`; sviluppo e realizzazione di sensori opto-elettronici per applicazioni IEEM (conferenze ICNMTA 2002, IBA 2003); studio di emissione di elettroni secondari da metalli e diamante CVD drogato con B (ICNMTA 2002). In programma autunno-inverno 2003: Installazione del microscopio su SIRAD in modo NON-assiale; misure di risoluzione superficiale con griglie TEM; misure di efficienza usando diodi PIN con sottili strati di metallizzazione (oro, aluminio,...) e materiali speciali. Finanziamento INFN richiesto per montare lo IEEM assialmente. Si richiede: (1) una nuova camera, (2) un supporto anti-vibrante con adeguata rigidita` tra microscopio, portacampioni, e (3) un sistema di accoppiamento meccanico specchio-lenti-sensore ottico; (4) un portacampioni e (5) della movimentazione micrometrica da vuoto commerciale con 5 gradi di liberta`: X,Y,Z e due di tilt per assicurare coplanarita` del campione con la lente di immersione dello IEEM; (6) un MCP anulare ad alta risoluzione con fosforo; per l’allineamento del fascio lungo l’asse dello IEEM: (7) due alimentatori +/- 10 kV DC per alimentare sistema di deflessione di SIRAD; (8) un sistema di sensori di fascio (faraday cup segmentate; diodi PIN).

Photon-EEM CHAMBER at Univ. Padova UV lamp commercial PEEM to be recycled as an IEEM shock absorbers This PEEM chamber does NOT satisfy experimental and mechanical requirements for SEE studies at SIRAD. Will be recycled only for startup tests. A new optimized chamber will be needed for axial installation!

Photon-EEM IMAGES with SIRAD PSD sensor 40 m TEM grid AXIAL IEEM Project two optical paths slow CCD camera 250 m field of view fast PSD annular MCP and phosphor The first SIRAD IEEM opto-electronic sensor is a PSD (Position Sensitive Device): the charge produced by impacting photons is split by a thin resistive layer into four charges. Measuring the four charges allows the determination of the photon impact position. In ideal conditions the resolution is better than 400 linear points; i.e. better than 1 m on the target. The rise time of 1.5 s puts the maximum ion handling rate at ~3×104 Hz (Poisson). Image intensifier is needed by PSD to ensure large signal and hence good lateral resolution.

NOVEL fast 2D opto-electronic sensor for the SIRAD IEEM AXIAL IEEM Project linear CCD array (1024 pixels) Note: no image intensifier! cylindrical lens linear CCD array (1024 pixels) beam splitter Un beam splitter sdoppia il segnale luminoso su due percorsi ottici ortogonali. Due lenti cilindriche, una per percorso ottico ed ortogonali tra loro, trasformano gli spot luminosi circolari in spot di forma laminare. Le lamine luminose incidono quindi ortogonalmente su due CCD lineari che restituiscono le coordinate trasverse del segnale primario. Un prototipo di questo sensore e` stato sviluppato recentemente dal gruppo SIRAD. Si ottengono risoluzioni di 1000 punti lineari e massimi ion impact rates di 104 Hz. Questo sensore digitale presenta importanti vantaggi rispetto al sensore PSD analogico: easy multiple hit rejection, hot channel masking, l’intensificatore di immagine non e` necessario.

preliminare IEEM non-assiale (0o) Installazione temporanea camera PEEM su SIRAD nell’autunno 2003 per prime prove con IONI. mechanical constraints of immersion lens of IEEM >65o phosphor MCP SIRAD chamber  UV Lamp Ion beam Sample recycled PEEM chamber e e e Errore di parallasse  d’ordine della risoluzione del microscopio. BAD!  ion SEE active volume in depth (1 micron) ------- +++++++

IEEM assiale GOALS 2004 Inverno: Primavera/Estate: Autunno/Inverno: progetto e costruzione della nuova camera di irraggiamento; costruzione del sistema antivibrante e del sistema di misurazione delle vibrazioni; progetto e costruzione della meccanica dello specchio anulare; acquisto MCP anulare; acquisto alimentatori DC per l’allineamento del fascio con lo IEEM; disegno del sistema dei sensori di fascio; acquisto movimentazione del porta-campioni. Primavera/Estate: test ed installazione della camera su SIRAD; test di inserimento del fascio lungo lo IEEM; misure di efficienza e risoluzione dello IEEM assiale; Autunno/Inverno: installazione di un sistema di test basato su SDRAM; risultati preliminari.

IEEM test: SDRAM SEU mapping IEEM Map 104 Bits in field of view effective SEE resolution (in depth) SDRAM DAQ DataBase 1 X1,Y1 R1,C1 2 .. N XN,YN RN,CN Post Processing IEEM DAQ (X1,Y1) (X2,Y2)

INFN PISA/Univ. Cassino Struttura, FTE, tasks, … INFN PISA/Univ. Cassino Ricercatori: Wyss J. R.U. 50%, Res. Nazionale Tecnologi: Di Stefano R., R.U. 50% INFN PADOVA Nigro M., P.O. 50%, Res. Locale Giubilato P., Dott. 50% Khomenkov V., Borsista 40% Rando R., Dott. 20% Cester A., R.U. 40% Tecnici: Pantano D., Univ. 20% INFN ROMA2 Bertazzoni S., R.U. 70%, Res. Locale DiGiovenale D., Dott. 70% Salmeri M., R.U. 70% Tasks 2004: Progetto e realizzazione: nuova camera di scattering per IEEM per la configurazione assiale (vedi figura); supporto anti-vibrante della camera di scattering; sistema per misurare vibrazioni; accoppiamento dello specchio anulare ad inclinazione variabile (vedi figura). Acquisto finestra di quarzo. Costruzione sistema di allineamento e diagnostica per l’allineamento del fascio con lo IEEM; acquisto e messa in opera del porta-campioni di precisione (5 gradi di liberta`); acquisto di un rivelatore di elettroni secondari: un MCP di 4 cm anulare (vedi figura); messa in opera dello IEEM assiale sulla linea SIRAD. Realizzazione di uno speciale sistema di test dello IEEM basato su SDRAM curando: compatibilita` con operazione dello IEEM e la camera di scattering; controllo, sincronizzazione e gestione dello IEEM e del front-end dello SDRAM (rivelazione di single event upsets nello SDRAM, di impatti ionici con lo IEEM e loro correlazione).

Preventivi 2004 (kEuro) Pisa Padova Roma2 TOT 25 48 20 Nazionali: Viaggi Nazionali: Cassino-LNL 2 PD-LNL RM-LNL 3 Esteri: congressi Cons. Meccanica specchio, specchio, finestra di quarzo 2 Sistema e diagnostica per centatura del fascio nello IEEM 4 Materiale elettronico 3 Meccanica varia 5 Produzione PCB Metabolismo Software progettazione elettronica (FPGA) totale consumo 13 11 Invent. Camera scattering 15 Portacampioni (5 assi) 18 PC dedicato ai test 2 Sistemi di sviluppo (TCP-IP) 1 2 alimentatori centratura fascio (+/- 10kV) 8 supporto antivibraz. Stazione saldatura SMD totale invent. 17 MCP forato 5 31 4 TOT 25 48 20