La presentazione è in caricamento. Aspetta per favore

La presentazione è in caricamento. Aspetta per favore

Upgrade for high Luminosity - a list of things to do / to understand Contributi da Davide, Roberta, Alessia Martellotti Roma 9 /10 /2014.

Presentazioni simili


Presentazione sul tema: "Upgrade for high Luminosity - a list of things to do / to understand Contributi da Davide, Roberta, Alessia Martellotti Roma 9 /10 /2014."— Transcript della presentazione:

1 Upgrade for high Luminosity - a list of things to do / to understand Contributi da Davide, Roberta, Alessia Martellotti Roma 9 /10 /2014

2 Can we reduce the DIALOG dead time (digit. formation time) ? Confirm/understand % of correlated e uncorrelated hits Better understand the long CARIOCA dead time Are GEM well suited for performance required in M2M3R1 ?  # Tests-Measurements to do as soon as we have beam # Something on Analysis # Remind of the performance  upgrade necessary / desirable

3 inefficiency (effective dead time in ns) DIALOG formation time (ns) Inefficiency induced by DIALOG strongly changes with the formation time.  A reduction of few ns in the formation time would give a strong inefficiency reduction. The inefficiency is also very sensitive to the muon time distribution (here assumed a gaussian with peack value at 11 ns)  Timing optimization could be different depending on the Luminosity. At low luminosity we could be more efficient for high P muons and at high luminosity more efficient for low P muons arriving later… INEFFICIENCY (effective dead time) OF MUON HITS at small dead time values DIALOG dead time

4 (Ho intervistato Sandro Cadeddu) Il tempo di formazione del segnale digitale si può regolare a passi di circa 3ns da un minimo di circa 6 ns fino a un massimo di circa 27 ns. Usando il tempo massimo (come nella gran parte dei dati raccolti), con l’OR di più canali fisici nel canale logico, non si può mai avere più di un hit nello stesso BC Ad alta rate, visto che la distribuzione temporale degli hit è larga (~~25 ns), con un tempo corto di formazione l’OR può ripartire nello stesso BC. L’aumento di hit nel BC corrente non cambia nulla per il tracking e la MisID. Per quanto riguarda il timing, il SYNC può dare una misura di tempo sbagliata (prende l’ultimo che arriva). Questo non mi sembra un vero problema : -Non credo che sia necessario ma eventualmente si potrebbero fare run di timing a bassa rate o con tempo di formazione lungo DIALOG dead time – can be reduced ?

5 Other drawback ? -Instability - Noise ….. Measurements (a la Giacomo) with short and long formation time Look at the time distribution in the BC or with TAE events Measure efficiency  Test on beam short formation time DIALOG dead time – can be reduced ?

6 Correlated/uncorrelated hits - measure OR- AND on beam Old measurements (see Giacomo muon meeting 18, 25 Feb 2013) - readout with FE of M2-M5 in OR - And Repete measurements at current energy (richiesta solo stabilità delle condizioni, non necessaria alta luminosità – fare le misure all’inizio) - with maximal DIALOG formation time (to avoid AND inefficiency) - AND-OR also for M1 (per indicazioni sulla natura degli hit in M1) - AND-OR in M2 - M5 with only one gap per FE (switch off HV on the first and the second gap of the bigap) A measurement of correlated/uncorrelated hits can be done (a la Davide) from the rate on physical channel counters with one or two gaps on. - with one gap on per bi-gap we can COMPARE the two measurements

7 OSSERVAZIONE In M1 abbiamo una sola gap per FE e abbiamo aumentato la tensione di circa 100 V (rispetto ad M2) per avere un Guadagno doppio e quindi una migliore efficienza…. Questo è una buona cosa per le tracce penetranti che vogliamo rivelare ma per quanto riguarda il dead time ha un effetto deleterio. Infatti il fondo di bassa energia è di «single gap tracks» e quindi è uguale nella bi-gap e nella single-gap dove però abbiamo alzato il guadagno di un fattore 2 peggiorando l’effetto di saturazione dell’amplificatore in M1R2 rispetto a M2R2 Questo può mettere in crisi la possibilità di alimentare una sola gap per FE nelle regioni ad altissima occupancy  Importante fare i test menzionati con una sola gap alimentata

8 Tempo morto del CARIOCA Misure di rate sui canali fisici vs Luminosità Fare misure con più alta statistica in modo da poter misurare bene il dead time nelle diverse regioni (anche R3, R4). BLU R1 ROSSO R2 VERDE R3 R4 Ogni punto è un rapporto di rate misurate a due luminosità in un PAD. Lo spread verticale delle misure è dovuto all’ errore statistico Le misure in R3 R4 non permettono di determinare la slope che misura il tempo morto del CARIOCA

9 Interessante separare la dipendenza dalla capacità del detector e la dipendenza dalla carica rilasciata dalle particelle nelle diverse regioni  Fare misure a 2 Luminosità con 2 HV diverse  2 tempi morti diversi corrispondenti ai due Guadagni diversi nella stessa regione (la spiegazione che ci diamo è che per grande carica rilasciata si ha saturazione dell’amplificatore e allungamento del tempo morto) Le misure si possono fare appena sono raggiunte condizioni stabili di alta luminosità. - Le vecchie misure erano fatte integrando i conteggi in 1 secondo. - Non risulta che ci siano difficoltà ad aumentare molto il tempo (l’unica condizione è la stabilità della luminosità nel tempo di misura - il tempo totale necessario per fare tutta la misura dipende molto poco dal tempo di integrazione) Tempo morto del CARIOCA Misure di rate sui canali fisici vs Luminosità

10 Analisi In M2 abbiamo misurato un tempo morto del Carioca molto più lungo di quanto ci si aspettava per una Mip. La interpretazione attuale è che questo sia dovuto alla grossa carica rilasciata dal low energy background con conseguente saturazione dell’amplificatore… Per testare questa interpretazione possiamo confrontare il tempo morto in M2R2 con quello in M1R2. Se l’interpretazione è giusta mi aspetto di misurare un dead time medio più basso in M1R2 dove mi aspetto una percentuale molto più alta di Mip Risultato ??? Nelle camere di M1 dietro la parete misuriamo una rate molto più alta (vedi Giacomo). Nelle camere dietro le riinterazioni nel materiale della stazione e il back splash dal calorimetro potrebbe dare effetti simili al fondo di bassa energia in M2…  Confrontare dead time CARIOCA misurato separatamente per camere davanti e camere dietro la parete.

11 Riguardo al confronto davanti dietro: significativa e piccolissima differenza Nelle camere dietro dove si misura una rate più alta, si misura anche un dead time maggiore Davide: Non sembra che M1 abbia un tempo morto minore di M2 Interpretation ???

12 GEM A parte il vantaggio della resistenza alla radiazione, sono le GEM adatte/ottimali per lavorare in M2R1 M3R1 ? - non mi riferisco (solo) alla risoluzione temporale/efficienza ma alla - rate di hit di fondo (generazione di single gap tracks nei piani sottili di materiale di alta densità vicino al gas) Finora gli studi fatti hanno riguardato soprattutto le MWPC. La misura AND-OR in M1 ci potrebbe dare delle indicazioni riguardo a questo punto Si possono avere informazioni dal Monte Carlo ? - anche se il MC quantitativamente non dà la percentuale di hit scorrelati che misuriamo nelle MWPC, potremmo comunque vedere se le GEM sono relativamente meglio o peggio delle MWPC ? Sono possibili altre misure ?

13 Inefficiencies reported in the TDR inefficiency from CARIOCA inefficiency mainly from DIALOG Following my simulation DIALOG inefficiency is underestimated Remind of performance

14 UPGRADE General comment Before deciding the final strategy it would be important to verify the possibility of reducing the DIALOG dead time. If we can significantly reduce it..… For what inefficiency is concerned: # It could be sufficient to make PAD detectors M2R1 M2R2 M3R1 (M3R2) + PAD readout in M2R3 and M5R4 going down to inefficiencies order of 1% in M2R1, M4R1, M5R1 and M5R4 (and lower in all the other regions) - Note that inefficiency in M3R2 with the present layout is at the same level of M4R1, M5R1 that are already pad detectors # The inefficiency goes down to order of 1% in M2R1 with pad = logical pad - If this solution brings to too many channels/cables  OR of two X-adjacent pads in the FE would reduce by a factor 2 the cables with no change of inefficiency and almost no change in MisID

15 For what MisID is concerned : With several % of pad occupancy we will have a very high occupancy in the FOIs  very high accidental probability # Assuming the rates reported in the TDR table and with present detector PAD occupancy goes up to ~50% in M5R4, ~ 9% - 4% in M2R1-M2R2 eliminating ghosts with a PAD detector occupancy goes down by > (~) a factor 2  necessary but not sufficient for a good performance locally (unless we have a good surprise from shielding - but simulated M2 shielding effect was already considered)  - PAD detector in M2R1 M2R2 M3R1 (M3R2) necessary - PAD readout in M5R4 necessary PAD occupancy goes up to ~2.5% - 2% in M2R3-M2R4  - PAD readout in M2R3, M2R4 usefull (more for MUID than for efficiency) Once eliminated the ghosts we cannot do much more for MUID but in the inner region we could still improve with a pad size X=2X, Y=1/2Y (it would permit to reduce YFOI) #... too many channels …

16 Spares

17 dead time inefficiencies Given a dead time of the electronics, the induced inefficiency significantly depend on the time distributions of the background and muon signals on the FE. # For the response of the bi-gap to background hits, I used the time distribution measured for MinBias TAE events (smoothed) # For the muons I assumed a gaussian: Peak 11ns, σ = 5ns Both are approximations that should be better tuned. M2R1 pad time For backgr hits For muon hits

18  Inefficiency induced by CARIOCA dead time at 40 MHz will be higher w.r.t. the case of 20 MHz (+ 15% for wires + 14% for cathodes) BCR = 40 MHz Inefficiency expressed in δeff Measured ns inefficiency = δ eff R* following dead time formula R*/R h = (1- δ eff R*) (δ eff in ns, R*=rate measured/0.7 in GHz) inefficiency (effective dead time δeff)  Inefficiency is higher for muon hits than for background hits In the case of DIALOG the inefficiency depends critically on the assumptions made background hits (FE counters) - Muon hits

19 Rates of particles (no ghosts) at L=2x10 33 Rates in kHz/cm 2 Simulation input: Foreseen rates reported in TDR Note : -The effect simulated of the new shielding to be added at M2-inner has been put in -The effect of the last shielding already added at M5R4, has to be evaluated and put in

20 Inefficiency = 5 11 23 % at 162 327 590 kHz/cm2 Logical pad occupancy Rate/cm 2 (kHz) EXAMPLE: M2R1 present detector (TS=95cm 2 ) X,Y= 6+8 phys.channels per Trig. Sect. 48x8 crossings per chamber (0.63x3.1 ~ 2cm 2 ) Important inefficiency of a single pad hit by a muon 5 11 23 % at 162 327 590 kHz/cm2 Reconstructed hits (with ghosts) Real particles The 3 red vertical lines correspond to the rates foreseen at L=2x10 33 in the chamber of the region having minimal, average, maximal population inefficiency Important contribution of ghosts 8

21 In M2R1, M3R1 inefficiency comes only from CARIOCA dead time. In the regions where we have pads Ored in the readout, DIALOG inefficiency is important. In most regions the inefficiency will come essentially from the ‘’DIALOG dead time’’ (18 ns assumed) MinAverMax 5.011.0 23.0 % 2.07.5 13.0 0.73.9 9.3 0.01.7 7.4 0.73.2 6.9 Inefficiencies reported in TDR Inefficiencies from my simulation (different definitions but significant differences) Effect of DIALOG seems to be important not only in M5R4  Can we further reduce DIALOG formation time ?  Possibly increase nODE number in other regions 9

22 Inefficiency: very large improvement 0.4 0.7 1.5 % at 162 327 590 kHz/cm 2 MisID: No ghosts  improvement using the usual FOI With this Ypad size, one could use a smaller FOI (in Y) with further improvement. M2R1 PAD DETECTOR X=2X, Y=1/2Y of logical pad 384 pads per chamber (1.26x1.6 ~ 2 cm 2 ) M2R1 PRESENT DETECTOR (TS = 95 cm 2 ) X,Y= 6+8 phys.channels per Trig. Sect. 48x8 crossings/chamber (0.63x3.1 ~ 2cm 2 ) Inefficiency : 5 11 23 % at 162 327 590 kHz/cm 2 MisID: many ghosts Logical pad occupancy Rate/cm 2 (kHz) Switching off one gap 11 Pad occupancy Rate/cm 2 (kHz)

23 M2R1 PAD DETECTOR X=2X, Y=Y of logical pad 192 pads per chamber (1.26x3.2 ~ 4 cm 2 ) Inefficiency increases: 0.8 1.6 3.3 % MisID: ~ the same using the standard FOI but no further improvement is possible using a smaller FOI. Pad occupancy Rate/cm 2 (kHz) Inefficiency: 0.4 0.7 1.5 % at 162 327 590 kHz/cm 2 MisID: With this Ypad size, one could use a smaller FOI (in Y) with further improvement. M2R1 PAD DETECTOR X=2X, Y=1/2Y of logical pad 384 pads per chamber (1.26x1.6 ~ 2 cm 2 ) 12 Rate/cm 2 (kHz) Pad occupancy

24 M2R2 PRESENT DETECTOR (TS=380 cm 2 ) X,Y= 12+16 phys.ch. =12 + 4 logic. per TS 48x4=192 crossings/chamber (1.26x6.3~8 cm 2 ) M2R2 PAD DETECTOR X=2X, Y=1/2Y of logical (it is convenient) 192 pads per chamber (2.5x3.1 ~ 8 cm 2 ) large improvement: 0.1 0.6 1.1 % MisID  Improvement (no ghosts)  possible further improvement reducing YFOI Pad occupancy Rate/cm 2 (kHz) Inefficiency : 2 7.5 13 % at 15 52 97 kHz/cm2 Rate/cm 2 (kHz) HITS in Trigger Sector – pad occupancy 13 /48

25 M2R2 PAD DETECTOR X=2X, Y=Y of logical pads 96 pads per chamber (2.5x6.3 ~ 16 cm 2 ) Pad occupancy MisID : Going back to the Y pad size = 6.3 cm, we have lost the possibility of reducing FOI having a lower MisID with ~ the same muon matching efficiency. Inefficiency : 0.3 1.3 2.4 % M2R2 PAD DETECTOR X=2X, Y=1/2Y of logical (it is convenient) 192 pads per chamber (2.5x3.1 ~ 8 cm 2 ) Inefficiency : 0.1 0.6 1.1 % MisID :  possible further improvement reducing YFOI Pad occupancy Rate/cm 2 (kHz) 14

26 M3R1 PRESENT DETECTOR (TS = 109 cm 2 ) X,Y= 6+8 phys. channels (48 crossings/TS) 384 crossings per chamber (0.63x3.1 ~2 cm 2 ) Logical pad occupancy Inefficiency: 0.7 3.2 6.9 % at 39 123 216 kHz/cm 2 Rate/cm 2 (kHz) M3R1 PAD DETECTOR X=2X, Y=Y (#phys chan. = #logical pad/2) 192 pads per chamber (1.26x3.1 ~4 cm 2 ) Inefficiency: 0.2 0.6 1.0 % MisID:  improvement (no ghosts) ~ same FOI can be used. Pad occupancy Rate/cm 2 (kHz) 15

27 M3R1 PAD DETECTOR X=2X, Y=Y (#phys chan. = #logical pad/2) 192 pads per chamber (1.26x3.1 ~4 cm 2 ) Inefficiency: 0.2 0.6 1.0 % MisID:  improvement (no ghosts) ~ same FOI can be used. Pad occupancy Reducing granularity to 96 pads  Inefficiency increases = 0.3 1.2 2.3 % M3R1 PAD detector X=4X, Y=Y (#phys. chan. = #logical pad /4) 96 pads per chamber (2.5x3.1 ~ 8 cm 2 ) Pad occupancy CARIOCA inefficiency can be recovered building the pad detector with smaller physical channels OR-ed in the DIALOG (without increasing output cables) What cannot be recovered is the increase of MisID if FOI must be increased to save muon matching efficiency 16 Rate/cm 2 (kHz)

28 M2R3 X Y= 24x4=96 phys. channels  24+ 4 logic. strips per TS Area TS = 60x50=3000 cm 2 With inefficiency due to DIALOG formation time = 18 ns = 3.9 % at 5.4 kHz/cm 2 (the average rate in the region) Here a gaussian with peak value = 11ns and σ = 5ns was assumed for the time distribution of the muon hits in the bi-gap. A uniform rate in the trigger sector was also assumed. This is not fully correct… nevertheless this value is significantly higher w.r.t. what reported in the TDR (2.6 %) And what is relevant is that, if I use the same time distribution used for the background hits, I get a much smaller inefficiency: 2.2 % (to be compared with 2.6% of TDR) HITS in Trigger Sector – pad occupancy Rate/cm 2 (kHz) Real particles Reconstructed hits /96

29 M2R4 present detector (TS=12000 cm 2 ) X Y= 24x4=96 phys. channels  24+ 4 logic. strips per TS Area TS = 120x100=3000 cm 2 Inefficiency comes from DIALOG 0. 1.7 7.4 % at 0.12 0.63 2.6 kHz/cm 2 HITS in Trigger Sector – pad occupancy /96

30 M5R4 present set up (TS=18480 cm 2 ) X,Y= 24+4 phys. ch. = 6+4 logic. Ch. per TS 24 crossings per TS (~770 cm 2 ) ONLY CARIOCA dead time inefficiency simulated 2.3 % at 9 kHz Pad occupancy Rate/cm 2 (kHz) HITS in the Trigger Sector Also DIALOG dead time simulated. Inefficiency = 1.3, 9, 30 % at 0.2, 2, 9 kHz/cm 2 Inefficiency from DIALOG (formation 18ns) to be revised : TAE time distribution of M2R1 was used Rate/cm 2 (kHz)


Scaricare ppt "Upgrade for high Luminosity - a list of things to do / to understand Contributi da Davide, Roberta, Alessia Martellotti Roma 9 /10 /2014."

Presentazioni simili


Annunci Google