Single scintillating crystal 48 × 48 × 10mm SiPM readout on both faces, 16 × 16 pixels of size 3 × 3mm Faces readout identical and independent, with both time and energy measurement for every pixel 4DMPET Obiettivo principale: sviluppo di un modulo PET 4D di nuova generazione, ad altissime prestazioni facilmente ottimizzabile per diverse applicazioni dell' imaging nuclearr informazioni molto accurate sulla posizione dell'evento in 3 dimensioni e un segnale di timing mantenendo al tempo stesso una elevata efficienza intrinseca. Completamente compatibile con MRI scanner Bari, Pisa, Perugia,Torino Resp. naz. : M. G. Bisogni Esp. finanziato aa Referee: V. Bonvicini, M. Bucciolini PUBBLICAZIONI 1) G. De Luca et al. Time performance investigation of a new PET detector module: simulations and Measurements, Submitted NIMA Proc.of ICFDT ) F. Pennazio et al.: Simulations of the 4DMPET SiPM-based PET module, Conf records IEEE NSS-MIC ) G. De Luca et al., Signal shape of a PET detector based on LSO:Ce,Ca crystals and SiPM,, Conf records IEEE NSS-MIC 2011
Stato, risultati, criticita’
Progetti FIRB e PRIN FIRB2012: “Innovative photo-detectors and 3D integrated readout electronics for next generation MRI-compatible PET bio-imaging” PI: Prof. Sergio Saponara UniPisa DIEET Partners: Unipi (Difi+DIIET), UniLe (PoliBa), UniPa, INFN- TO Aree ING-INF01-FIS07 PRIN :INnovative Solutions for In-beam DosimEtry in hadrontherapy PI: Prof. Alberto Del Guerra Partners: Roma “La Sapienza” (SBAI), PoliBa, UniTo (DiFi), INFN
SEVEN Sviluppo di detector multinucleari per risonanza magnetica a 7 Tesla Sezione di Pisa (A. Retico) Sezione dell’Aquila (M. Alecci)
SEVEN activity A. Retico - SEVEN 5 Coil design and development: 1. PI - Single-loop coils ( 1 H): simulation, prototypes and comparison the tuning and matching procedures 1.5 T and 7 T 1. PI - TEM 7 T: simulations and prototypes Collaboration with Jim Tropp (GE senior scientist, March & June-July 2011) Integration to the 7 T 2. PI - Phased 7 T: simulations and prototypes Collaboration with Jim Tropp (GE senior scientist, July 2011) “Attempt” to integrate to the 7 T
SEVEN activity PI & AQ - Dual-tuned RF coils ( 1 H- 31 P): – Many simulations and prototypes – Final 7 T design now ready to be integrated to the 7 T scanner In Pisa 5.AQ - Dual-tuned Microstrip RF coil ( 1 H- 31 P): – Developed for 4 T and 9.4 T – To be scaled to 7 T magnetic field. 4. A. Vitacolonna, S. Romanzetti, J. Felder, N. J. Shah, A. Sotgiu, and M. Alecci, RF Field Optimization of 4T Double-Tuned Surface TEM Resonators for 1H/23Na MRI, Proc. International Society of Magnetic Resonance in Medicine, 19th Scientific Meeting, Montreal, Canada, May 09-13, pg (2011). M. Polsoni, A. Vitacolonna, A. Galante, A. Sotgiu, N.J. Shah, and M. Alecci, Design and Workbench Testing of a 9.4T Double-Tuned (1H/23Na) Surface Resonator, II Congresso Scientifico dell’Associazione Italiana di Risonanza Magnetica in Medicina e dell’Italian Chapter dell’ISMRM, Università di Roma La Sapienza, 31 marzo-1 aprile 2011, page 27. R. Stara, N. Fontana, A. Monorchio, G. Manara, A. Del Guerra, G. Tiberi, L. Biagi, M. Alfonsetti, A. Galante, A. Vitacolonna, M. Alecci, M. Tosetti and A. Retico, RF coil design for low and high field MRI: numerical methods and measurements, IEEE NSS and MIC Conference Records, Oct. 2011, Valencia, Spain. Tesi 2011: R. Stara: Tesi di Laurea Magistrale in Fisica (PI) 5. A. Retico - SEVEN
Status of the IMAGO7 centre 7 9th June th December 2011
Milestones 2011 The pulse sequences for SNR estimation, B1 mapping and SAR evaluation at 7T have not been implemented yet on the 7T scanner (the installation has been completed in Dec 2011). The appropriate sequences have been identified, implemented and tested on the 1.5 T scanner. They should be imported and revised for the 7T system. The access to the IMAGO7 site is now restricted to few authorized researchers. This task is supposed to be completed in few months (June 2012). A. Retico - SEVEN Criticità Attualmente accessi controllati al sito: – Necessaria attestazione di idoneità a svolgere attività lavorativa in campo magnetico da parte del medico competente. – Attivazione a Pisa del servizio di prevenzione e protezione: disposizione di un protocollo adeguato per la sorveglianza sanitaria degli esposti. Integrazione coil-scanner 7 T (prevista per giugno 2012): – Necessaria stretta collaborazione con personale General Electrics
Partecipazione a PRIN e FIRB PRIN: Caratterizzazione del circuito neurale dell'emozione durante il neurosviluppo. Mod A: Prof. P. Brambilla, Dip. di Psichiatria, Università di Udine Mod B: Università di Pavia Mod B: Università di Trento Mod B: Università di Pisa (Neuropsichiatria e Stella Maris) Mod B: INFN (A. Retico con afferenza di personale dip. Fis. Unipi e CNR), trattamento e eleborazione dati e immagini. Le varie unità di ricerca ospiteranno le competenze anche di ricercatori degli istituti IRCCS Medea, IRCCS Stella Maris, Imago7 e Istituto Superiore di Sanità. L'unità INFN si occuperebbe dell'elaborazione dei dati di risonanza magnetica strutturale, mettendo a disposizione le tecniche e le competenze acquisite negli ultimi anni nell'ambito delle analisi di immagini biomediche. L'afferenza all'unità INFN dei ricercatori di Imago7 renderà possibile effettuare studi comparativi tra dati MRI acquisiti con sistemi 1.5, 3 e 7 Tesla, in modo da confrontare la rilevanza diagnostica delle tecniche di imaging di risonanza magnetica ad alto campo. FIRB: Prevenzione delle malattie psichiatriche utilizzando marker neurali identificati con la risonanza magnetica Mod A: Prof. P. Brambilla, Dip. di Psichiatria, Università di Udine Mod B: Università di Verona (Informatica) Mod B: INFN (A. Retico con afferenza di personale dip. Fis. Unipi, Stella Maris, Imago7 e Dip. di Neuropsichiatria), raccolta dati ed analisi dati e immagini.
Resoconto finanziario fondi 2011 MIMEConsumoInventarioLicenze SW PISA Trasferte Pisa- StellaMaris (Retico) Condensatori non magnetici di alta qualità a capacità fissa o variabile. Tubi di plexiglass (vari diametri). Lastre di plexiglass per supporti. Cavi e connettori non magnetici. Substrati in DUROID da stampare. Licenza SW FEKO per 2 anni L’Aquila (anticipo2012) 0 viaggi a Pisa Condensatori non magnetici di alta qualità a capacità fissa o variabile. Cavi e connettori non magnetici. Substrati in PVC o plexiglass per supporti. Lastre di rame. PC da laboratorio