RMN TECNICHE DI IMAGIN A CONFRONTO: G.PICCOLI FOLLOW UP DEL CARDIOPATICO CON PATOLOGIA DELL’AORTA ASCENDENTE UDINE 28 – 5 - 2011 TECNICHE DI IMAGIN A CONFRONTO: RMN G.PICCOLI S.O.C DI DIAGNOSTICA ANGIOGRAFICA E RADIOLOGIA INTERVENTISTICA AZ OSPEDALIERO UNIVERISTARIA S.M.M UDINE
LA DIAGNOSTICA ANGIORADIOLOGICA MR CT
IMAGING INTEGRATO : RUOLO DI ECO, TC E RM
- + + - MR CT US ( SPECT ) CONFRONTO TRA METODICHE RISOLUZIONE SPAZIALE + - RISOLUZIONE DI CONTRASTO ( SPECT ) MR CT US SOGLIA DEL “mm”
ARCO AORTICO TRATTO TUBULARE GIUNZIONE SINO-TUBULARE TORACICA DISCENDENTE BULBO AORTA DIAFRAMMATICA AORTACELIACA
ANEURISMI DELLA AORTA TORACICA
ECG GATING
METODO DI MISURAZIONE DEI DIAMETRI UTILIZZANDO LE IMMAGINI ASSIALI AXIAL CUT A B SPESSORE PARETE COMPRESA THROMBUS INCLUDED ! LENTH = B - A Effetto “Fetta di salame”
3 D MPR MEASURES VESSEL ANALYSIS IMAGE DATA WORK FLOW CLINICAL PLAN CT ANGIO MR ANGIO WORKSTATION 3 D MPR MEASURES VESSEL ANALYSIS CLINICAL PLAN
IMAGE DATA ANALISYS
COME MISURARE IL BULBO AORTICO ?
MR : X-RAY MRA AND CE-MRA RADIO FREQUENCY PULSE MAGNETIC FIELD NON IODINATED CONTRAST
MRA AND CE-MRA MRA (SENZA MEZZO DI CONTRASTO) TSE T1 E T2 W (+FAT SUP) ECG GATED : PROSPETTICHE E RETROSPETTICHE TSE T1 E T2 W (+FAT SUP) PHASE CONTRAST CINE SSFP (CINE TRUE FISP) CE- MRA (CON GADOLINIO) VIBE FLASH 3D BH FLASH 3D ECHO NAV GATED T1 W GE
RMN STANDARD PER FU DURATA TEMPO : 15-20 MINUTI TSE T1 W (ASSIALI, CORONALI, PARASAG) CINE TRUFISP : 4 CH, 2CH, 3CH, VALV AORT PHASE CONTRAST VALVOLA AORTICA NORMALMENTE NON VIENE INIETTATO MDC
SENZA MEZZO DI CONTRASTO VALUTAZIONE AORTICA COMPLETA RM SENZA GADOLINIO SENZA MEZZO DI CONTRASTO
DILATAZIONE DEL BULBO AORTICO IN VALVOLA TRICUSPIDE SSFP TSE PC TSE
DILATAZIONE TRATTO TUBULARE IN VALVOLA AORTICA BICUSPIDE
VALVOLA AORTICA ?
VALUTAZIONE MORFOLOGICA DELLA VALVOLA AORTICA RMN TEE ANTIGRADE FLOW REGURGITATION
RISCONTRO OCCASIONALE IN CORSO DI RM PER FU T1 W T2 W
DISSEZIONE AORTA ASCENDENTE IN PAZIENTE ASINTOMATICO
70 ANNI 52 MM BULBO E Ao TUBULARE, VALVOLA BICUSPIDE PROTESI BIOVALSALVA
CONFRONTO RMN E ANGIO-TC POST INTERVENTO RMN 3D RMN TC
VALUTAZIONE DELLE ANASTOMOSI CHIRURGICHE E TEVAR CT MR CT MR
RCA RMN CON MDC IL FOLLOW-UP DEL PAZIENTE OPERATO PAZIENTE DI 50 ANNI OPERATO PER DISSEZIONE ACUTA TIPO 1 De Bakey RCA RMN CON MDC
IL FOLLOW-UP DEL PAZIENTE OPERATO RCA TEE ANGIOGRAFIA
IL FOLLOW-UP DEL PAZIENTE OPERATO
DISSEZIONE OPERATA : F.U. RMN TSE T 1 W ECG GATED
ANEURISMA DISSECANTE
FOLLOW-UP DI DISSEZIONE B : ANEURISMA DISSECANTE 6.5 DISSECTING ANEURYSM
… FINAL RESULT
MR AXIAL MORPHOLIGIC STUDY GRE SSFP TSE T1 W
MR:3D RECONSTRUCTION ANGIO RMN 3D
MR AFTER TEVAR: GADOLINIUM INJECTION ARTERIOUS PHASE STEADY STATE (5 MIN) STEADY STATE HIGH RESOLUTION NAVIGATOR ECHO TIME
METODICA IDEALE NEL FOLLOW-UP ASSIEME A TTE CONCLUSIONI OTTIMO COMPROMESSO RISOLUZIONE DI CONTRASTO BASSA INVASIVITA’ PANORAMICITA’ RISOLUZIONE SPAZIALE LIMITI ACCESSIBILITA’ COMPLESSITA’ TECNICA TEMPO ESAME METODICA IDEALE NEL FOLLOW-UP ASSIEME A TTE
ANEURYSM : DISTAL ENDOLEAK CT CT MR MR CT VENOUS PHASE MR STEADY STATE INTERCOSTAL ARTERY CT MR
64 STRATI SENZA GATING CARDIACO 64 STRATI CON GATING CARDIACO RADICE AORTICA RADICE AORTICA 64 STRATI SENZA GATING CARDIACO 64 STRATI CON GATING CARDIACO
ECG GATED CT
ANEURISMA TORACO ADDOMINALE CORONARIE CAROTIDI
ANEURISMA TORACO ADDOMINALE FUNZIONE VENTRICOLARE SN CORONARIA DESTRA
ANEURISMA SENI VALSALVA
WITHOUT ECG TRIGGER WITH ECG TRIGGER
CANCER RISK AND RADIATION DOSE EQUIVALENT OF CHEST X-RAY EXAM AND CANCER RISK DOSE Msv INTERNATIONAL COMMISSION OF RADIOLOGICAL PROTECTION