RinNOVA SOLAR TANK IDRAULICA CALDAIA
2
CIRCUITO IDRAULICO
3
POMPA COMPITO IN RISCALDAMENTO FAR CIRCOLARE L’ACQUA NELL’IMPIANTO TERMICO IN SANITARIO FAR CIRCOLARE L’ACQUA NELLO SCAMBIATORE SANITARIO CARATTERISTICHE COMPATTO DISAREATORE INCORPORATO DATI MODELLO WILO INTNFSL 12/6 2 VELOCITA’ ALIMENTATO A 230 Vc.a. GRADO DI PROTEZIONE IP44
4
SCAMBIATORE PRIMARIO E CONDENSANTE
COMPITO SCAMBIARE CALORE TRA ACQUA PRIMARIA E FIAMMA SCAMBIARE CALORE TRA ACQUA PRIMARIA E FUMI CARATTERISTICHE COSTRUITO CON ELEMENTI IN ALLUMINIO ELEMENTI ALETTATI PER AUMENTARE SCAMBIO TERMICO ED EVACQUAZIONE FUMI BRUCIATORE CENTRALE ALETTE DI SCAMBIO TERMICO E CONVOGLIAMENTO FUMI BRUCIATORE INGRESSO ACQUA A plurality of heat exchanger sections A plurality of elongate fins defining the flue gas flow channels A means to guide the flue gas from the burner through the flow channels A means to promote unidirectional flue gas flow DATI 25 KW : 2 ELEMENTI 35 KW : 3 ELEMENTI ALETTE DI SCAMBIO TERMICO
5
SCAMBIATORE CONDENSANTE
PRINCIPIO DI FUNZIONAMENTO: PERCORSO FUMI PERCORSO ACQUA I FUMI SONO CONVOGLIATI AD ALTA VELOCITA’ VERSO L’ALTO ATTRAVERSO I CANALI CREATI DALLE ALETTE SUPERIORI. I FUMI POI SONO SPINTI VERSO IL BASSO ED IN QUESTO PERCORSO CEDONO IL LORO CALORE ALL’ACQUA CHE CIRCOLA NEL SENSO OPPOSTO PER FORZA DI GRAVITA LA CONDENSA CHE SI CREA ALL’INTERNO DELLO SCAMBIATORE SCENDE VERSO IL BASSO E PASSA NEL SIFONE. USCITA FUMI ACQUA PROFILO GUIDA FUMI (PERMETTE AI FUMI DI ANDARE SOLO VERSO L’ALTO) SCARICO CONDENSA
6
SCAMBIATORE CONDENSANTE
CARATTERISTICHE LE DIMENSIONI ED IL NUMERO DELLE ALETTE PERMETTE A QUESTO SCAMBIATORE DI AVERE UN OTTIMO SCAMBIO TERMICO GRAZIE ALL’ELEVATA SUPERFICIE DI SCAMBIO I PASSAGGI NEL LATO FUMI SONO MOLTO RISTRETTI PER AUMENTARE LA VELOCITA’ DEI FUMI STESSI ACQUA E FUMI SEGUONO UN PERCORSO IN CONTRCORRENTE: L’ACQUA FREDDA SCAMBIA CON I FUMI NEL PUNTO PIU’ BASSO IN MODO DA FAVORIRE LA CONDENSAZIONE
7
GRUPPO DI MANDATA SV CARATTERISTICHE MATERIALE COMPOSITO
ACCESSO E MANUTENZIONI FACILITATE COMPONENTI ASSEMBLATI VALVOLA TRE VIE PRESSOSTATO PRIMARIO BY-PASS TRASDUTTORE PRESSIONE CIRCUITO PRIMARIO BY PASS MANDATA SMABIATORE SANITARIO ESTERNO MANDATA RISCALDAMENTO OTTURATORE 3 VIE MOTORE 3 VIE
8
VALVOLA TRE VIE COMPITO
MODIFICARE IL CIRCUITO PRIMARIO IN RELAZIONE AL TIPO DI RICHIESTA (RISCALDAMENTO, SANITARIO/ANTIGELO) CARATTERISTICHE COMPOSTO DA: NUOVO MOTORE (PISTONCINO CON CORSA PIU’ LUNGA) 220 V, 9,35 KOHM NUOVO OTTURATORE (SENZA MOTORE POSIZIONATO IN RISCALDAMENTO) POSIZIONE MOTORE A RIPOSO: SANITARIO
9
MOTORE VALVOLA 3 VIE TENSIONE AL MOTORE 3 VIE CON GRUPPO IN OTTONE
TENSIONE AL MOTORE 3 VIE CON NUOVO GRUPPO IN MATERIALE COMPOSITO SANITARIO RISCALDAMENTO RISCALDAMENTO SANITARIO
10
CIRCUITO IDRAULICO TRASDUTTORE DI PRESSIONE (NOVITA’ 2011)
COMPONENTE DI SICUREZZA CHE VERIFICA LA PRESSIONE DELL’ACQUA ALL’INTERNO DELLA CALDAIA E DELL’IMPIANTO TERMICO. IL VALORE DI PRESSIONE VIENE TRADOTTO IN SEGNALE ELETTRICO E VISUALIZZATO NEL LCD DELLA CALDAIA. POSIZIONATO NELLA PARTE FRONTALE (FACILMENTE ACCESSIBILE) COMPOSTO DA: CONNETTORE A TRE CONTATTI (5V-GND-OUT) MEMBRANA MOLLA COLLEGATO ELETTRICAMNETE ALLA SCHEDA INTEGRATA ALIMENTAZIONE ELETTRICA 24 Vdc PRESSIONE DI INTERVENTO 0,35 bar INCREMETATA LA SENSIBILITA’ ABBINABILE AD IMPIANTI A VASO APERTO PERMETTE ALLA CALDAIA DI ATTIVARSI CON MINIME PRESSIONI QUALORA IL VALORE DI PRESSIONE RILEVATO FOSSE INFERIORE A 0,35 Bar: ANOMALIA SPECIFICA (E04)
11
NTC RISCALDAMENTO COMPITO
MONITORARE LA TEMPERATURA DEL CIRCUITO PRIMARIO PER: GESTIRE LA MODULAZIONE IN BASE ALLA TEMPERATURA RAGGIUNTA VERIFICARE LA CIRCOLAZIONE ACQUA PRIMARIA ATTRAVERSO LA VELOCITA DI VARIAZIONE DELLA TEMPERATURA CARATTERISTICHE INSTALLATO SUL TUBO D’ USCITA DALLO SCAMBIATORE PRIMARIO STESSO BETA DEGLI ALTRI NTC PER QUALSIASI GUASTO A QUESTA SONDA IL BRUCIATORE NON SI ACCENDE PER NESSUNA RICHIESTA